Availability: In Stock
NIR Spectrometer
Product Code: ATP8000
Ask About This Product
This product has a minimum quantity of 1000
application

The ATP8000 series SWIR fiber optic spectrometers, developed by Optosky, operate in the near-infrared range with a maximum spectral coverage of 900-2500 nm (customizable). Featuring a 512-pixel  thermoelectrically cooled (TEC) InGaAs linear array    detector, the CCD is maintained at a user-defined constant temperature (down to -30°C), significantly    reducing sensor noise and achieving a signal-to-noise ratio (SNR) 2× higher than competing products. This  design ensures measurement reliability unaffected by ambient temperature fluctuations.
The ATP8000 integrates an ultra-low noise CCD signal correlated double sampling (CDS) circuit with  <5 counts quantization noise (industry-leading). It supports SMA905 fiber or free-space optical input, outputs spectral data via USB 2.0/UART, and operates on a single +5V DC supply for seamless integration.


Detector
Detector type Cooled InGaAs Array CCD,Cooled down to-20ºC
Spectral range 900-1700nm, 900-2100nm, 900-2600 nm, 900-1700HR, 900-2100HR, 900-2500HR (Customized)
Effective pixels 512
Pixels dimension 50/25μm×250μm
Full well capacity 187.5 Me-
Detector model G11477
Sensitivity 0.95 A/ W
Dark noise 180 μV rms
Optical parameter
Focal distance 100 mm for incidence / 110 mm for output
Optical resolution 3-6nm (Custom configured grating grooves and slit size)
Incident Interface SMA905 connector,free space
Signal-to-noise >3000:1
Dynamic range 16666
Working temperature -10 to +50℃
Numberical aperture 0.11
Working humidity < 90%NC
Trigger YES(IN and OUT)
Cooling temperature -20°c
Scanning rate <200fps
Wavelength range 900-1700nm, 900-2100nm, 900-2600 nm, 900-1700HR, 900-2100HR, 900-2500HR (Customized)
Physical parameters
Dimensions 170×130×52.3 mm3
Weight 1.79kg
Sealing Anit-sweat
Optical configuration
Optical design f/4 crossed asymmetrical Czerny-Turner
Incident slit 50 μm (5, 10, 25, 50, 100, or 200 μm optional)
Electrical parameter
A/D conversion resolution 18 bit
Integration time 1 ms -50ms, 900-2500nmHR 1ms-40s, 900-1700nm
Interface USB 2.0
Supply voltage DC4.5 to 5.5 V (type @5V)
Operating current <3A
Storage temperature -20°C to +70°C

  • Detector: 512/1024-pixel InGaAs array
  • Spectral range :900-2500 nm(customizable sub-ranges)
  •  Cooling options: -15℃ (standard) / -30℃ (T3 series)
  •  Noise performance: Ultra-low noise correlated double sampling(CDS) circuit
  • Resolution: Slit-dependent
  • Integration time: 1 ms - 65 s
  • CCD parameters:256/512×1 pixel ,50/25×500 um
  • Power supply:5V DC±5%@<3A;
  •  Power Interfac: 2-pin connector with securing screws;
  • ADC: 18-bit (16-bit effective output) @ 500 kHz;
  • Optical Input Interfaces: SMA905 fiber optic or free-space;
  • Data output:USB2.0 & UART;
  • 20-pin expansion port

  • Food sorting;
  • Wastewater testing;
  • Water, protein, fat, fiber detection of crops;
  • Paper sorting;
  • On-line monitoring of traditional medicine production;
  • Solar panel testing

Do you have the software interface for C++?

ATP 6500 is equipped with SDK software for C++ development.

How long is the spectrometer warranty?

Leading industrial warranty is three year, and OEM project is offered a one-year warranty.

What is the price?

ATP 8000 prices range between USD16,380-USD25,880, free software and 1-year warranty,  contact us.

Why use NIR?

Non-destructive measurements

Little or no sample prep

Readings in milliseconds

Ease of operation

Accurate and precise

More FAQ Click Me!


Write a review

Note: HTML is not translated!