ATR9000(Old Model: ATP8200)is developed by Optosky(Attenuated Total Reflection, ATR), built-in MEMS Infrared Source, it employs Pyroelectric linear array sensor, in the ZnSe high performance material window measure ATR spectrum. Optosky exclusively designs Ultra-low noise CCD signal processing circuit, results in reducing sensor noise, improving improving SNR( 2 times higher SNR than competitors). Higher measuring reliability ensures results can not change with ambient temperature.
ATR9000 fit to measure samples in powder, fluid, easy-to-operate, it takes just few steps to complete measurement.
Detector | |
Detector type | Pyroelectric linear array sensor(ZnSe) |
Spectral range | 2.5-5 μm or 5.5-11μm |
Effective pixels | 256 pixels |
Pixels dimension | 50 μm x 417.5 μm or 60 μm x 500 μm |
Full well capacity | NA |
Sensitivity | NA |
Dark noise | NA |
Optical parameter | |
Optical resolution | NA |
Incident Interface | MEMS infrared source inside |
Signal-to-noise | NA |
Dynamic range | 75dB |
Working temperature | -10°c to + 45°c |
Numberical aperture | NA ATR |
Working humidity | < 90%RH No condensing |
Trigger | NA |
Cooling temperature | uncooled |
Full Well | NA |
Scanning rate | 10-1000 Hz |
Wavelength range | 2.5-5 μm(4000-2000 cm-1)or 5.5-11μm(1818-909 cm-1) |
Physical parameters | |
Dimensions | 106×85×30 mm3 |
Weight | 0.5kg |
Raman Spectrometer System Parameters | |
Operating Humidity | < 90%RH |
Optical configuration | |
Optical design | Linear Variable Filter, LVF |
Incident slit | >5000 hrs |
Electrical parameter | |
A/D conversion resolution | 16 bit |
Integration time | 30s |
Interface | USB 2.0 |
Supply voltage | 5V |
Operating current | <2 A |
Storage temperature | -20°C to +70°C0 |
Operating temperature | -10°c to + 45°c |
- Spectral Range:2.5-5 μm(4000-2000 cm-1)or 5.5-11μm(1818-909 cm-1)
- MIR(Attenuated Total Reflection, ATR)spectrometer
- Detector:Linear Pyroelectric linear array sensor(ZnSe)
- ATR window material:ZnSe
- Detector pixels:256pixels
- Ultra-low noise CCD signal processing circuit
- Built-in MEMS electrical Infared Source
- Measure Time:30s(Typical)
- 16 bit, 500 KHz ADC
- Data output port: USB2.0
- Power Supply:5V DC, <2A
- Food safety
- Dye analysis
- Material identification
- Anti-counterfeiting authentication
- The Environmental Monitoring of stack emissions, such as SO2,CO,CO2 etc.
- Defense & Security detection of TNT,Acetone, TATP, VX, Sarin etc.
- Life Sciences of NH3, SF6, ethylene etc.
- Industrial Process Monitoring for gas, liquid, or solid
- Biomedical, such as protein analysis, blood analysis, urine analysis
- Petrochemistry
- pharmaceutical industry
- Oil Material Analysis
- Drugs, Chemicals, Combustible & Explosives Analysis
Q:What is the wavelength range?
Spectral range:2.5-5 μm(4000-2000 cm-1)Or 5.5-11μm(1818-909 cm-1)
Q:What brands used for the detector?
A: 256pixels pyroelectric linear array sensor
Q:What is the size?
A: 106×85×30 mm3
Q:What is the weight?
A:The weight is about 0.5kg.
Q:What is the price?
A:Please contact us about the price.
Q: What is ATR technology?
A: Attenuated total reflection (ATR) is a sampling technique used in conjunction with infared spectroscopy which enables samples to be examined directly in the powder or liquid state without further preparation.