Availability: In Stock
Mini NIR Spectrometer
Product Code: ATP8600
Ask About This Product
This product has a minimum quantity of 1000
application

Micro spectrometer with small structure size. It uses a 256-pixel InGaAs linear array detector and integrates a reliable CCD installation and heat dissipation method to improve the measurement reliability of the ATP8600. At the same time, Optosky ATP8600 has specially customized an ultra-low noise CCD signal related double sampling processing circuit, which is the best in the industry.
ATP8600 can receive SMA905, FC/PC optical fiber input light or free space light, and output the measured spectral data through Type-C or UART port.
ATP8600 only requires a 5V DC power supply and can be directly powered by USB, which is very convenient for integration and use.

Model

Description

ATP8600

900-1700nm, SMA905 interface

ATP8600FBG

Signal demodulation for fiber optic sensors (C/L/C+L-wave segment), FC/PC interface

ATP8600-17TC

900-1700nm, detector cooling to - 15℃ (Requires auxiliary cooling)

ATP8600-25TC

900-2500nm, detector cooling to - 15℃ (Requires auxiliary cooling)

Detector
Pixels dimension 256 pixels
Full well capacity 13.75 Me-
Detector model Linear InGaAs CCD
Sensitivity 160 nV/e-
Pixel size 25μm × 25μm
Optical parameter
Dynamic range 14667
Working temperature -10-50℃
Working humidity <90%RH
Trigger USB Type-c or UART
Wavelength range 900-1700 nm, Customized (max.interval 750nm)
SNR >2255:1
Optical Design f/4, Crossed C-T
Physical parameters
Dimensions 102 x 57.5 x 29mm
Weight 280g
system parameter
power supply 5 DC ±5%
Size 5, 10, 25, 50, 100, 150, 200, 300μm
Electrical parameter
A/D conversion resolution 16 bits
Integration time 1ms-60s
Resolution 4-20 nm (Depend on the slit, the actual spectral range)
Operating current <0.8 A
Storage temperature -20 °C to +70 °C
Operating temperature -10°C to +50°C

  • Maximum operating spectral range: 900-2500nm ((Maximum width: 1400 nm);)
  • Ultra-low noise correlated double sampling circuit.
  • Spectral resolution: related to the width of the incident slit.
  • Integration time: 1ms- 65s (depends on detector).
  • CCD pixels: 256, 512 pixels.
  • Power supply: DC 5V.
  • ADC bit depth: 16 bits.
  • ADC sampling rate: 1MHz.
  • Optical input interface: SM905, FC/PC optical fiber interface or auto input from space.
  • Data output interface: Type-C and UART.
  • 10-pin expansion interface.

  • Food sorting

  • Waste water detection;

  • Detection of moisture, protein, fat and fiber in crops;

  • Paper sorting;

  • Online monitoring of Chinese medicine production;

  • Solar panel inspection;

  • FBGA fiber modem;

  • Laser wavelength monitoring.
What are NIR spectrometer from Optosky?

ATP8100 ultra-mini nir spectrometer
ATP8600 low cost, uncooled, FBGA, nir spectrometer, 900-1700nm (max.interval 750nm)
ATP8730 High resolution 0.08nm resolution, up to 30KHz frame rate
ATP8000 High performance 2-stage TEC cooled InGaAs, max, 800-2600nm, replace ocean NIR spectrometer
ATP8000T3 Highest performance 3-stage TEC cooled down to -30℃, low noise, and low dark current


More FAQ Click Me!

Write a review