Availability: In Stock
MIR Spectrometer
Download Data Sheet
Product Code: ATP8300
Ask About This Product
This product has a minimum quantity of 1000
application

ATP8300 is the third-generation high-performance mid-infrared fiber optic spectrometer newly developed by Optosky.  It  adopts  the sixth-generation  newly designed optical platform and exquisitely crafted optical components of Optosky, and has achieved excellent optical sensitivity and spectral resolution. At the same time, it uses a variety of high-performance detectors, including high-sensitivity  back-illuminated linear CCD. CCD uses semiconductor refrigeration technology. CCD can work in a set constant temperature environment (minimum - 10ºC), thus greatly reducing the noise of the sensor, has achieved an excellent signal-to-noise ratio (about 2 times higher than that of similar competitors), and has improved the  measurement reliability of the ATP8300, and the measurement results do not change with the ambient temperature.

Model

Feature

ATP8300-30

1.0-3.0μm

ATP8300-50

1.0-5.0μm


Detector
Detector type Linear CCD
Spectral range ATP8300-30: 1.0-3.0μm ATP8300-50: 1.0-5.5μm
Optical parameter
Focal distance 98 mm for incidence / 107 mm for output
Optical resolution ATP8300-30: 20nm ATP8300-50: 40nm
Incident Interface SMA905 fiber optic interface or free space
Signal-to-noise 3000:1
Dynamic range 10000:1
Cooling temperature - 15℃
Wavelength range 900-1700nm, 900-2100nm, 900-2600 nm, 1510-1590nm
Physical parameters
Dimensions 208×120×47mm
Weight 1.5- 1.7 Kg
Optical configuration
Optical design F/4 crossed asymmetrical Czerny-Turner
Incident slit 5, 10, 25, 50, 100, 150, 200 μm optional, other sizes can be customized
Electrical parameter
A/D conversion resolution 18 bits (input 16 bits)
Data output interface USB 2.0
Power supply DC 12V±10%
Working current <2.3A
Integration time 400μs~10s
Operating current Universal version:<2.8 A T3version:<5.0 A
Storage temperature -20°C to +70°C
Operating temperature -10 to +50℃
  • Mid-infrared band: 1.0-3.0μm or 1.0-5.0μm.
  • Optional within the maximum band range.
  • Resolution: 20nm or 40nm, depending on wavelength range and slit.
  • Ultra-low noise CCD signal processing circuit.
  • Optical path structure: cross C-T.
  • Detector TEC refrigeration, higher stability and reliability.
  • Power supply: DC 12V±10% @ <2.3A.
  • 18 bit, 570KHz ADC (actual output 16bit).
  • Optical input interface: SMA905 or free space.
  • Data output interface: USB2.0 (High speed) or UART.
  • 20-pin double-row programmable external expansion interface.
  • Mid-infrared spectral analysis
  • Material analysis
  • Gas composition analysis
  • Plastic Sorting
  • Reflectance, transmittance detection
  • Fruit sorting

Write a review

Note: HTML is not translated!
Related Products