Confocal Raman Microscope
Confocal Raman Microscope
5
5
Availability: In Stock
Confocal Raman Microscope
Product Code: ATR8100
application
- The ATR8100 Raman spectroscopy series combines the advantages of microscopes and Raman spectrometers. The Micro-Raman detection platform is a visual and precise positioning Raman detection platform, which allows the user to detect the Raman signals of different surface states on the sample, and can be displayed simultaneously on the computer, which is greatly Facilitates Raman micro-area detection.
- ATR8100 raman instrument is equipped with an objective lens specially designed for the Raman system, which makes the laser spot close to the diffraction limit. The focus information is accurately and intuitively displayed on the computer through a 5-megapixel camera, which improves the quality of the Raman spectrum.
- ATR8100 adopts a unique moving part without optical path switching (patented), which perfectly solves the loss of optical path for camera imaging, realizes the separation of camera imaging and Raman signal collection, and obtains the best signal strength.
- At the same time, ATR8100 uses high-performance Raman specially optimized for micro-Raman systems. It is industry-leading in terms of sensitivity, SNR, stability, etc., providing a strong guarantee for Raman research.
Model | Feature |
ATR8100BS | Base |
ATR8100AF | Auto Focus |
ATR8100MP | Mapping type (highest configuration, auto-focus, auto-scan) |
Confocal Raman Microscope | |
Wavelength | 200nm~1100nm |
SNR | >2000:1 |
Dynamic Range | 13000:1 |
Detector | 2048 Pixel |
Pixel | 14 μm * 14 μm |
Spectral Resolution | 3-6 cm-1 (Customized slit & range) |
Spectral Stability | σ/μ < 0.5% (COT 8 hours) |
Temperature Stability | Spectral shift ≤ 1 cm-1 (10~40 ℃) |
Spot Diameter | >1μm |
Interface | USB2.0 |
Microscope Camera | 5-mega pixel Camera |
Focus Method | conjugate focus |
Laser Stability | σ/μ <±0.2% |
Laser Linewidth | 0.08 nm |
Battery Life | Built-in Li-battery, > 4 hours, and customized. |
Laser Power | >350mW (Software Adjustable) |
- Ultra-high sensitivity, SNR >2000:1
- HDcapacitive touch screen
- Windows operating system
- Built-in lithium battery
- Quick positioning and focus
- Micron-level light spot
- 5 million pixel cameras
- Excitation wavelength: 532, 633, 785, 830, 1064nm optional
- Equipped with high-performance spectrometer
- Nanoparticles And New Materials
- Universities And Research Institutes
- Biotechnology: Biological Sciences
- Biopharma: Forensic Medicine Identification
- Material Science
- Chemistry: Medical Immunoassay
- Agriculture And Food Identification: Food & Beverage
- Water Pollution Analysis
- Energy: Gem And Inorganic Mineral Identification
- Environment: Environmental Science
Q: What is the ATR8100 Series Confocal Raman Microscope?A: The ATR8100 Series Confocal Raman Microscope is a versatile instrument that combines the capabilities of a microscope with those of a Raman spectrometer. It provides a precise and visual platform for detecting Raman signals from different surface states of a sample. The results are displayed on a computer, greatly facilitating Raman micro-area detection.
Q: What are the key features of the ATR8100 Series?A: Key features of the ATR8100 Series include:Ultra-high sensitivity with a signal-to-noise ratio (SNR) greater than 2000:1, ensuring clear and accurate Raman spectra.HD capacitive touch screen for easy and intuitive operation.Windows operating system for a user-friendly interface and software compatibility.Built-in lithium battery for enhanced portability and flexibility in various experimental environments.Quick positioning and focus capabilities for efficient sample analysis.Micron-level light spot for high precision in targeting small sample areas.5-megapixel camera for clear and detailed imaging.Multiple excitation wavelengths (532, 633, 785, 830, 1064 nm) to suit various types of samples and experimental needs.High-performance spectrometer for detailed and accurate Raman signal detection.
Q: How does the ATR8100 Series enhance Raman signal detection?A: The ATR8100 Series is equipped with a specially designed objective lens that brings the laser spot close to the diffraction limit, ensuring high precision in Raman signal collection. The system also incorporates a patented moving part that avoids optical path switching, effectively preventing signal loss during camera imaging. This design separates camera imaging from Raman signal collection, optimizing signal strength and quality.
Q: What applications can benefit from using the ATR8100 Series?A: The ATR8100 Series is suitable for a wide range of applications, including:Nanoparticles and new materials researchUniversities and research institutesBiotechnology and biological sciencesBiopharma, particularly forensic medicine identificationMaterial science and chemistry, including medical immunoassaysAgriculture and food identification, such as food and beverage quality controlWater pollution analysisEnergy research, including gem and inorganic mineral identificationEnvironmental science and monitoring
Q: What makes the ATR8100 Series suitable for micro-area detection?A: The ATR8100 Series is ideal for micro-area detection due to its:High spatial resolution, which enables the detection of Raman signals from very small areas on the sample.Quick positioning and focus features that make it easy to locate and analyze specific areas of interest.Ability to display Raman signals in real time on a computer, facilitating precise and efficient micro-area analysis.
Q: How user-friendly is the ATR8100 Series?A: The ATR8100 Series is designed for ease of use, featuring an HD capacitive touch screen and a Windows operating system for intuitive operation. Its automated functions and straightforward controls make it accessible for users with varying levels of experience, requiring minimal training.
Q: Does the ATR8100 Series require frequent maintenance?A: No, the ATR8100 Series is designed to minimize maintenance needs. Its robust build and high-quality components ensure reliable performance over time, reducing the frequency of maintenance required.
Q: Can the ATR8100 Series be used for portable or field applications?A: Yes, the ATR8100 Series is equipped with a built-in lithium battery, making it portable and suitable for field applications. This feature allows for flexibility in various experimental settings, whether in the lab or in the field.
Q: What are the advantages of the ATR8100 Series' optical path design?A: The ATR8100 Series features a unique design that avoids optical path switching, which eliminates signal loss during camera imaging. This design also ensures that the camera imaging and Raman signal collection processes are separate, maximizing signal intensity and accuracy for high-quality Raman spectra.