Availability: In Stock
infrared spectrometer
Download Data Sheet
Product Code: ATP8900-2-C
Ask About This Product
This product has a minimum quantity of 1000
application
ATP8900-2-C FTIR spectrometer with two compartments for two channels independent operation, In-situ diffuse reflection and in-situ transmission cell synchronization, no necessary to
replace attachments frequently. 

Configured to room temperature detector and low temperature LN MCT detector sychronization with a max. scan rate 60K ATP8900-2-C FTIR spectrometer with compact and rigid design to fit to multi-mode measurement of transmission, ATR , diffuse reflection, specular reflection. Dual sample compartment requires no frequent replacement can improve efficiency. It's widely applied to measure solid, liquid, and gas in the third party lab and in-situ characteristics of many categories of catalysts.
Infrared spectroscopy
Light Source Long life vacuum cooling ceramic light source, 1550K
ftir spectrometer
Channels/Compartments Auto-switch 2 channels, 2 compartments
Spectral Range 8000~350 cm-1
Resolution ≤1cm-1
Wave number accuracy ≤0.01cm-1
Interferometer Michelson interferometer with wear free and reliability of 10 year guaranty, with cube-corner mirror resist mechanical and temperature vibration
Beam splitter ZnSe, KBr
Detector LN MCT detector / DLATGS detector
Laser Solid laser, 10 years warranty
Software Win10 software functions including FTIR spectra measure, spectra database pretreatment, spectra comparison, standard peaks finding, user self-build library, quantitative analysis, auto-deduct diamond/CO2 absorption peak, intelligent peak finding warning, one-button test result evaluate, export report and print. Auto switch channels, configured to quick scan speed of 20K, 40K, 60K and diffuse reflectance measure change to K-M spectra
Wave number precision ≤0.01cm-1
  • 2 channels & 2 sample compartments for independent operation
  • Easy to auto-switch channels on the software Auto adjust 6 scan speed with 2.5K-3.0K
  • Software can auto-transfer in K-M format for convenient comparison with diffuse reflection spectra
  • Save or import background spectra for comparing, reminder valid time function
  • Sample compartment is spacious for various bigger IR attachment
  • Optical path in good collimated, no necessary to replace large attachments with 2 compartment
  • ZnSe beam splitter with little maintenance for optional
Chemical Reaction Kinetics of Catalysts
Online catalysts at high temperature, high pressure or vacuum catalytic performance
Catalytic reaction mechanics and process
Catalytic surface absorption activities and performances
Catalytic characteristics of Acid/Alkali
New catalysts experiment database
Ingredients identification and structure analysis of catalysts sample
Multi-tasks measurements
Experimenters are always receive various samples for measurement, such as solid, liquid and
gas and in order to make a different analysis, say transmission modules, ATR attachments.
When it's necessary to replace the different FTIR attachments, ATP8900-2-C can customize immovable attachments, auto-switch optical path at accuracy.
Heating in-situ transmission cell
High temperature/pressure in-situ diffuse reflection cell
High temperature/vacuum in-situ diffuse reflection cell
Low temperature/vacuum in-situ diffuse reflection cell
Positive transitivity (paralleled incident light
Diffuse transmission (integrating sphere attachments)
Reflectivity measure (reflective angle of 10°, 30°, 45°, 80°, and changed degree etc)
ATR measurement (optional crystals: diamond, ZnSe, Ge)
Solid, liquid, gas sample transmission characteristics
Pharm & Life Science
Protein conformation and quantification
Quantification for Active Pharmaceutical Ingredients and excipient in water solution
Microorganism Identification
Characterization for the volatility and stability of medicine combined with TGA module
Polymer and Chemical Products
Detection and Characterization for the volatility and decomposition combined with TGA module
Monitoring reaction process in lab combined with MIR fiber probe module
Surface analysis
Detection and Characterization for the Ultra-Thin film and mono-layer film
Characterization for the erosion process
Material Science
Detection of Emissivity of building materials
Evaluation for Optical material such as Infrared windows and mirrors
Semi-conductor Silicon Industry
Different non-metal film measure
Quality control medium carbon / oxygen impurity identification
Soil Analysis
Soil fertility and organic evaluation
Soil properties research

What is Infrared Spectroscopy?

Infrared spectroscopy tells the interaction of infrared radiation with matter. 


What is Infrared Spectroscopy used for?

It can be used to identify and study chemical substances in solid, liquid or gas state.


What does Infrared Spectroscopy tell you?

Infrared spectroscopy detect molecule groups based on absorption spectroscopy.


How much does an Infrared Spectroscopy cost?

Contact us for a quote.


How does Infrared Spectroscopy work?

It detect molecule absorption spectrum.


How to choose Infrared Spectroscopy?

1st, Is it a well-established brand with good reputatioon?

2nd, How high performance of Infrared spectrometer?

3rd, How good services of Infrared spectrometers?


Where to buy Infrared Spectroscopy?

Optosky website or local distributors.


Why choose optosky Infrared Spectroscopy?

Optosky is a well-established brand with good reputatioon.

Optosky Infrared spectrometer includes FTIR & ATR

Optosky provides high performance cost less.


More FAQ Click Me!