It's ideal spectrometer used in uv vis spectrophotometer.
| Detector | |
| Detector type | Linear COMS |
| Effective pixels | 2048 |
| Pixels dimension | 14μm×200μm |
| Detector model | Hamamatsu s11639 |
| Sensitivity | 1300 V/(lx·s) |
| Dark noise | 13 RMS @ 13 ˚C |
| Optical parameter | |
| detect range | 200-1100 nm |
| Focal distance | 40 mm for incidence / 60 mm for output |
| Optical resolution | 0.1-3 nm |
| Incident Interface | SMA905 connector |
| Signal-to-noise | >600 : 1 |
| Dynamic range | 8.5 x 107 (system); 2000:1 for a single acquisition |
| Working temperature | -10°c to + 50°c |
| Numberical aperture | 0.11 |
| Working humidity | < 90%RH |
| Trigger | YES(IN and OUT) |
| Cooling temperature | uncooled |
| Full Well | NA |
| Scanning rate | < 1 kfps |
| Wavelength range | 350-800nm, 180-410nm, 200-850nm, 300-1100 nm, 200-1050nm, 780-1100nm |
| Slit Size | 50 μm (5, 10, 25, 100, 150, 200 um are optional) |
| Optical Design | f/4 crossed asymmetrical Czerny-Turner |
| Physical parameters | |
| Dimensions | 102×72×36.3 mm^3 |
| Weight | 0.38kg |
| Sealing | Anti-sweat |
| Electrical parameter | |
| A/D conversion resolution | 16 bit |
| Integration time | 1 ms - 80 s |
| Interface | USB 2.0 |
| Supply voltage | DC4.5 to 5.5 V (type @5V) |
| Operating current | 170mA@Typ. |
| Storage temperature | -30°C to +70°C |
| Operating temperature | -25-50 °C |
- Built-in Pulsed Xenon Driver.
- Fiber input, Signal Output line at one side for better Integration.
- Detector: Linear CMOS.
- Pixel size: 2048pixels.
- Max spectral range: 190-1100 nm(Maximum span of 800nm ).
- Spectral resolution: 0.1-3nm (Depending on spectral range and slit width).
- Optical Path: crossed CT.
- Integration times: 1ms-65s.
- Supply voltage: DC 5V or USB Power.
- 16 bit, 2MHz A/D Converter.
- Interface: USB2.0 (High speed) or UART.
- 30-pin dual-row programmable external expansion interface.
- Spectrophotometer
- Environment Instrument (exhaust gas and water quality)
- Transmittance, reflectance detection
- Spectral analysis/radiation spectrophotometry analysis
- Laser wavelength measurement
- Spectrophotometer
- Environment Instrument (exhaust gas and water quality)
- Transmittance, reflectance detection
- Spectral analysis/radiation spectrophotometry analysis
- Laser wavelength measurement
Q: What is unique feature of ATP2002?
A: It has Flash Xenon light source Drive inside, is uv-vis spectrometer.
Q:What is the wavelength range?
A:ATP2002 is available in 200-400nm 350-800nm,180-380nm,200-850nm,300-1100nm,200-1000nm.You can also choose to customize the wavelength range.
Q:What is the sensitivity?
A:ATP2002 is upgraded to 1300 V/(lx·s), that is 2 times higher improved.
Q:What is the resolution?
A:Resolution of ATP2002 can be customized between 0.1-3 nm corresponding to the different slit.
Q:What is signal-to-noise ratio?
A:SNR of ATP2002 is upgraded to >500:1.
Q:What brands used for the detector?
A:CCD of ATP2002 is used Hamamatsu made in Japan, the best brand of CCD.
Q:What is the size?
A:The size of ATP2002 is 102mm×72mm×34 mm, equal to 4×2.8×1.3 inch.
Q:What is the weight?
A:The ATP2002 is about 0.2kg.
Q:Do you have the software interface for C++, Labview?
A:Yes,we are equipped with SDK software for C++, labview development. If you need it, we can also send the software to you, you can install the software yourself.
Q:How long is the spectrometer warranty?
A:Leading industrial warranty is three year, and OEM project is offered a one-year warranty.
Q:What is the price?
A:ATP 2002 price is between USD4680~4980, please contact us if you want to know the specific price.