ATR3110LT Scientifically Portable Raman Spectrometer, LT means long time integration time. It especially fits to weak signal; long integration time reach up to 30minutes suit to laboratory research. Unique reliability ensures accurate detect result. Excellent low stray condition makes a wide application to biochemical analyzer, food safety, pharmaceutical engineer.
Raman Spectrometer System Parameters | |
Interface | USB2.0 |
Integration time | 4ms-30min |
Operating temperature | -10~40 ℃ |
Operating Humidity | < 95% |
Weight | 5.5kg |
Raman spectrometer Relibility | |
Spectral Stability | σ/μ < 0.5% (COT 8 hours) |
Temperature Stability | Shift ≤ 1 cm-1 (10-40 ℃) |
Spectral Range Change Stability | <±5% (in 5 ~ 40 ℃) |
Raman Spectrometer Optical Parameters | |
Spectral Range | 250-2300cm-1 200-3000cm-1 200-3800cm-1 |
Resolution | 250-2300cm-1: 6 200-3000cm-1: 8 200-3800cm-1:10 |
SNR | >3000:1 (918 cm-1 of Acetonitrile , 10s accumulation, 200mW) |
Focal Length | 98 mm for incidence and output |
Sensitivity | QE>40%, 6.5 μV/e- |
Raman spectrometer Detector | |
Detector Model | Scientific & fast cooed FFT CCD optical path:f/4 C-T |
Cooled down to | -20 ℃ |
Dynamic range | 75000:1 |
Pixel Size | 1044*64 Area Array CCD |
Raman Spectrometer Laser Parameters | |
Excitation Wavelength | 785nm (+/-1nm) |
Laser Output | ≥550 mW |
Power Stability | σ/μ <±0.2% |
Ultra-low Dark Current, especially fit to long time integration time setting;
Suit to low signal materials measure;
Ultra-high sensitivity FFT-CCD TECooled;
Detector cooled down to -20 ℃;
Ultra-low noise circuit;
Powerful embedded software;
Fluorescence background elimination;
Peak finding and display;
USB 2.0;
User-friendly interface;
ATR3110LT System | |||
Interface | USB 2.0 | ||
Integration Time | 4ms - 30 min | ||
Voltage | DC 5V(+/-5%),4.5A | ||
Working Temp. | -10~40 ℃ | ||
Working Humidity | < 95% | ||
Dimension (L*W*H) | 30×22.5×13.2 cm3 | ||
Weight | 5.5 Kg | ||
Reliability | |||
Spectral Stability | σ/μ < 0.5% (COT 8 hours) | ||
Temperature Stability | Shift ≤ 1 cm-1 (10-40 ℃) | ||
Spectral intensity shift (in 5 ~ 40 ℃) | <±5% | ||
Optical Parameters | |||
Spectral Range (cm-1) | 250-2300 | 200-3000 | 200-3800 |
Resolution (cm-1) | 6 | 8 | 10 |
SNR | >3000:1 (918 cm-1 of Acetonitrile , 10s accumulation, 200mW) | ||
Entrance slit | 50 μm | ||
Optical system | f/4 C-T | ||
Focal distance | 98 mm for incidence and output | ||
Detector | |||
Models | Scientific fast cooed FFT CCD | ||
Detector cooled down to | -20 ℃ | ||
Detect Range | 200-1100 nm | ||
Effective pixels | 1044*64 Area Array CCD | ||
Dynamic Range | 75000:1 | ||
Pixel Size | 24μm×24μm | ||
Full Well | 300 Ke- | ||
Sensitivity | QE>40%, 6.5 μV/e- | ||
Laser |
Wavelength | 785nm (+/-1nm) |
FWHM | 0.08 nm |
MAX Power Output | ≥550 mW |
Power Stability | σ/μ <±0.2% |
Raman Probe | |
Working Distance | 6 mm |
OD | OD>8 |
NA | 0.3 |
Aperture | 7mm |
Art, Art of Work, Craft,Archaelogy,Antique
Bioscience and Medical diagnosis
Pharmaceutical Engineer
Forensic Analysis & Criminal Investigate
Agriculture and Food Safety
Gemstones Identification
Environmental Science
Geology & Mines exploration
Semi-conductor and solar energy
Q:What is the wavelength?
A:Optosky is available for wavelength of 785nm,266nm,532nm,633nm,830nm,1064nm.
Q:What is the sensitivity?
A:QE>40%, 6.5 μV/e-
Q:What is the resolution range from 250~2300nm,200-3000nm,?
A:They are 6cm-1,8cm-1,10cm-1.
Q:what is signal-to-noise (SNR) ratio?
A:SNR >3000:1
Q:what brands used for the detector?
A:Hamamatscu scientific and fast cooled FFT CCD
Q:Do you have the software interface for Labview?
A:Yes, the software can be equipped with SDK software for Labview development.
Q:Do you have the software interface for Matlab development?
A:Our engineer can develop for OEM project.
Q:How long is Raman instrument warranty?
A:Industrial leading one-year warranty.
Q:What is the price?