Availability: In Stock
Scientifical Portable Raman Spectrometer
Download Data Sheet
Product Code: ATR3110LT
Ask About This Product
application

ATR3110LT Scientifically Portable Raman Spectrometer, LT means long time integration time. It especially fits to weak signal; long integration time reach up to 30minutes suit to laboratory research. Unique reliability ensures accurate detect result. Excellent low stray condition makes a wide application to biochemical analyzer, food safety, pharmaceutical engineer. 


Raman Spectrometer System Parameters
Interface USB2.0
Integration time 4ms-30min
Operating temperature -10~40 ℃
Operating Humidity < 95%
Weight 5.5kg
Raman spectrometer Relibility
Spectral Stability σ/μ < 0.5% (COT 8 hours)
Temperature Stability Shift ≤ 1 cm-1 (10-40 ℃)
Spectral Range Change Stability <±5% (in 5 ~ 40 ℃)
Raman Spectrometer Optical Parameters
Spectral Range 250-2300cm-1 200-3000cm-1 200-3800cm-1
Resolution 250-2300cm-1: 6 200-3000cm-1: 8 200-3800cm-1:10
SNR >3000:1 (918 cm-1 of Acetonitrile , 10s accumulation, 200mW)
Focal Length 98 mm for incidence and output
Sensitivity QE>40%, 6.5 μV/e-
Raman spectrometer Detector
Detector Model Scientific & fast cooed FFT CCD optical path:f/4 C-T
Cooled down to -20 ℃
Dynamic range 75000:1
Pixel Size 1044*64 Area Array CCD
Raman Spectrometer Laser Parameters
Excitation Wavelength 785nm (+/-1nm)
Laser Output ≥550 mW
Power Stability σ/μ <±0.2%

Ultra-low Dark Current, especially fit to long time integration time setting;

Suit to low signal materials measure;

Ultra-high sensitivity FFT-CCD TECooled; 

Detector cooled down to -20 ℃;

Ultra-low noise circuit;

Powerful embedded software;

Fluorescence background elimination; 

Peak finding and display;

USB 2.0;

User-friendly interface;

ATR3110LT System

Interface

USB 2.0

Integration Time

4ms - 30 min

Voltage

DC 5V(+/-5%),4.5A

Working Temp.

-10~40 ℃

Working Humidity

< 95%

Dimension (L*W*H)

30×22.5×13.2 cm3

Weight

5.5 Kg

Reliability

Spectral Stability

σ/μ < 0.5% (COT 8 hours)

Temperature Stability

Shift ≤ 1 cm-1 (10-40 ℃)

Spectral intensity shift

(in 5 ~ 40 ℃)

<±5%

Optical Parameters

Spectral Range (cm-1)

250-2300

200-3000

200-3800

Resolution (cm-1)

6

8

10

 

SNR

>3000:1 (918 cm-1 of Acetonitrile , 10s accumulation, 200mW)

Entrance slit

50 μm

Optical system

f/4 C-T

Focal distance

98 mm for incidence and output

Detector

Models

Scientific fast cooed FFT CCD

Detector cooled down to

-20 ℃

Detect Range

200-1100 nm

Effective pixels

1044*64 Area Array CCD

Dynamic Range

75000:1

Pixel Size

24μm×24μm

Full Well

300 Ke-

Sensitivity

QE>40%, 6.5 μV/e-

Laser

Wavelength

785nm (+/-1nm)

FWHM

0.08 nm

MAX Power Output

≥550 mW

Power Stability

σ/μ <±0.2%

Raman Probe

Working Distance

6 mm

OD

OD>8

NA

0.3

Aperture

7mm

Art, Art of Work, Craft,Archaelogy,Antique

Bioscience and Medical diagnosis

Pharmaceutical Engineer

Forensic Analysis & Criminal Investigate

Agriculture and Food Safety

Gemstones Identification

Environmental Science

Geology & Mines exploration

Semi-conductor and solar energy

Q:What is the wavelength?

A:Optosky is available for wavelength of 785nm,266nm,532nm,633nm,830nm,1064nm.

Q:What is the sensitivity?

A:QE>40%, 6.5 μV/e-

Q:What is the resolution range from 250~2300nm,200-3000nm,?

A:They are 6cm-1,8cm-1,10cm-1.

Q:what is signal-to-noise (SNR) ratio?

A:SNR  >3000:1

Q:what brands used for the detector?

A:Hamamatscu scientific and fast cooled FFT CCD

Q:Do you have the software interface for Labview?

A:Yes, the software can be equipped with SDK software for Labview development.

Q:Do you have the software interface for Matlab development?

A:Our engineer can develop for OEM project.

Q:How long is Raman instrument warranty?

A:Industrial leading one-year warranty.

Q:What is the price?

A:Contact to quote.

More FAQ Click Me!

Write a review

Note: HTML is not translated!