XRF & Portable Raman Spectrometer
Availability: In Stock
XRF & Portable Raman Spectrometer
Product Code: ATRX3000
application
Description
ATRX3000 is a portable Raman spectrometer + XRF combined instrument launched by Optosky based on more than 20 years of Raman spectroscopy development experience. ATRX3000 has two built-in modules, Raman analyzer and XRF analyzer, which complement and authenticate each other and learn from each other. Raman spectroscopy is a molecular spectroscopy measurement method, XRF is an atomic spectroscopy measurement method, Raman spectroscopy is a semi-quantitative test method, and XRF is a quantitative test method. Combining the two spectral methods with instruments, ATRX3000 can be used as a fast, non-destructive and safe detection technology. It has the characteristics of fast, accurate, good reproducibility, simple sample pre-treatment, compact and portable, and widely applicable. It is suitable for on-site operations and can be used for food safety, public safety, drug safety, plastics and other aspects of testing. It can detect trace amounts of illegal additives, pesticide and veterinary hormone residues, adulterated harmful substances in food.
ATRX3000 is a portable Raman spectrometer + XRF combined instrument launched by Optosky based on more than 20 years of Raman spectroscopy development experience. ATRX3000 has two built-in modules, Raman analyzer and XRF analyzer, which complement and authenticate each other and learn from each other.
Raman spectroscopy is a molecular spectroscopy measurement method, XRF is an atomic spectroscopy measurement method, Raman spectroscopy is a semi-quantitative test method, and XRF is a quantitative test method. Combining the two spectral methods with instruments, ATRX3000 can be used as a fast, non-destructive and safe detection technology. It has the characteristics of fast, accurate, good reproducibility, simple sample pre-treatment, compact and portable, and widely applicable. It is suitable for on-site operations and can be used for food safety, public safety, drug safety, plastics and other aspects of testing. It can detect trace amounts of illegal additives, pesticide and veterinary hormone residues, adulterated harmful substances in food.
Features
- Dual method detection: Raman spectroscopy + XRF;
- More accurate: molecular spectroscopy and atomic spectroscopy are mutually authenticated;
- Accurate automatic recognition algorithm, no need for manual spectrum reading;
- Sample form: constant solid, powder, film, liquid;
- 10'' capacitive touch screen
- Precision probe positioning device, laser spot alignment adjustment is very simple
- Multi-channel measurement device optional;
- USB 2.0, Bluetooth, WI FI, 4G module (optional);
- Touch screen and keyboard input;
- Friendly human-machine interface;
- Battery endurance > 5 hours;
- IP67 waterproof and dustproof;
Performance | Parameters |
Maximum number of samples measured at a time | 8 channels |
Sample form | Constant solid, powder, film, liquid; |
Interface | USB 2.0/LAN |
Touch screen | 10 inch capacitive touch screen |
Photographic evidence function | 3 million pixel camera |
Operating system | High security Android operating system |
Battery power supply time | >5 h |
Integration time | 4ms - 120s |
Power supply voltage | DC 19V( +/-5%) |
Operating temperature | -25~60 ℃ |
Operating humidity | < 95% |
Storage conditions | -35~75 ℃ , < 95% |
Dimensions (L*W*H) | 45.6 ×34.5 ×25.2 cm3 |
Weight | 12 Kg |
Center wavelength | 785nm ( +/-0.5nm), 1064nm optional |
Half-peak width | 0.08 nm |
Power stability | σ/μ<±0.2% |
Spectral intensity variation (in 5 ~ 40 ℃) | <±5% |
Maximum laser output power | ≥550 mW |
Spectral range | 250-2700 cm-1 |
Resolution | 4-6 cm-1 |
Signal-to-noise ratio | >570:1 |
Optical system | f/4 C-T cross symmetric optical path |
Focal length | 98 mm for incidence and output |
Model | Cooled high performance linear array CCD |
Detection range | 200-1100 nm |
Effective pixels | 2048 |
Dynamic range | 1300 :1 |
Sensitivity | 130 Photon @ 400 nm; 60 Photon @ 600 nm |
Spectral stability | σ/μ < 0.5% (COT 8 hours) |
Temperature stability | Spectral shift ≤ 1 cm-1 (10-40 ℃) |
Working distance | 6 mm |
Transmittance | OD>8 |
Numerical aperture | 0.3 |
Aperture | 7mm |
XRF energy resolution | 145eV |
XRF detection range | Mg(magnesium)—U(uranium) |
X-ray tube target | W/Ag/Rh target (optional) |
X-ray tube voltage | 50kV/200μA upper limit, tube pressure and current can be freely adjusted |