Availability: In Stock
Portable Dual-band Raman Instrument
Download Data Sheet
Product Code: ATR3200
Ask About This Product
application
  • In many cases in lab is uncertain of wavelengths better for their application, ATR3200 dual-band Raman spectrometer integrate two wavelengths laser sources to detect small sample. It requires no contact, no treatment to make an undestructive detect. This instrument has advantages of high performance-to-ratio, smart size can detect liquids, including fabrics, biology, alcoholics, crystals etc.
  • ATR3200 built-in 532nm, 633nm, 785nm Raman spectrometers, all of them employs cooled high sensitivity Raman signal enhanced CCD, high efficient Raman probe with a laser power up to 600mW narrow linewidth lasers, combined with high reliable optical design, circuit design, structure design, detect result is very stable, and super SNR.
  • ATR3200 built in 1064 Raman, employs ultra high cooled semi-conductor lasers, 2nd class cooled ultra high sensitivity InGaAs linear array CCD. As a result, with high performance, high sensitivity can fit to scientific research, medical instrument industry


Raman Spectrometer System Parameters
Interface WIFI,4G(Optional)
Operating System Android
Integration time 532: 1ms-120s 633: 1ms-64s 785: 4ms-120s 830: 4ms-120s 1064: 4ms-120s
Power Voltage AC 220V(+/-5%)
Operating temperature Touch screen, PC
Operating Humidity <95%
Dimension 800*500*300mm
Weight 27kg
Raman spectrometer Relibility
Spectral Stability <5%(COT 8 hours)
Temperature Stability ≤1cm-1
Spectral Range Change Stability <±5%
Raman Spectrometer Optical Parameters
Spectral Range 532: 200-3700cm-1 633: 200-2700cm-1 785: 200-2700cm-1; 200-3500cm-1, 200-4300cm-1 830: 200-2700cm-1 1064: 200-2600cm-1
Resolution 532: 200-3700cm-1 res. 8cm-1 633: 200-2700cm-1 res. 10cm-1 785: 200-2700cm-1; 200-3500cm-1, 200-4300cm-1 res. 6-10cm-1 830: 200-2700cm-1: 6cm-1 1064: 200-2600cm-1: 13cm-1
SNR 532: 1500:1 633: 3000:1 785: 3000:1 830: 3000:1 1064: 3000:1
Raman spectrometer Detector
Cooled down to -10℃
Dynamic range 532: 50000:1 633: 10000:1 785: 50000:1 830: 30000:1 1064: 80000:1
Raman Spectrometer Laser Parameters
Excitation Wavelength 532±0.5nm 633±0.5nm 785±0.5nm 830±0.5nm 1064±0.5nm
Laser Linewidth <0.1nm
Laser Output 532≥100mW 633≥100mW 785≥500mW 830≥500mW 1064≥500mW
Power Stability <±5%
Raman Spectrometer Probe
Operating Distance 6mm
Rayleigh Scatter Resistance OD>8
NA Raman Probe 0.3
Aperture 7mm
  • Dual bands:532, 633, 785, 1064nm (optional dual wavelengths combination);
  • High sensitivity, SNR>3000:1
  • High Stability
  • Hamamatscu CCD, excellent performance;
  • High performance spectrometer
  • USB2.0 connect to PC
  • Scientific research
  • Bioscience 
  • Forensic analysis 
  • Material science research
  • Medical immunology
  • Agricultural and food science
  • Waste water analysis
  • Gemstone and inorganic minerals identification
  • Environmental science



Q: What is the excitation laser?

A: ATR3200 is available in 532nm, 633nm, 785nm, 830nm, 1064nm. Can be customized dual wavelength.

Q: What is the wavelength number?

A: The wavelength number of ATR3200 is 200-2600nm, 200-3700nm

Q: What is the resolution?

A: Resolution of ATR3200 can be customized between 5-12nm corresponding to the channels and wavenumber.

Q: What is the size?

A: It's 350 × 296 × 172 mm.

Q: What is the weight? 

A: The weight is about 12 kg.

Q: What is the ATR3200 Raman spectrometer?

A: The ATR3200 is ideal for Dual-band Raman spectrometer. You can configure spectrometers for different applications depending on your requirements. Band ranges from 532 nm Up to 1064nm, the resolution can be selected from 5-12nm.

Q: What is ATR3200 used for?

A: The ATR3200 can be adapted to dual-band portable Raman spectrometer for various Science applications such as Scientific Research.

Q: How much does an ATR3200 dual-band portable Raman spectrometer cost?

A: USD70k/unit.

Q: How long is the spectrometer warranty?

A: One-year warranty.

Q: Where to buy ATR3200?

A: Optosky ATR3200 is in-stock, contact sales for more details.

Q: What is Dual-band Raman Spectrometer?
A: The Dual-band Raman Spectrometer combines two wavelengths available in one instrument. 532nm+785nm, 532nm+633nm,532nm+1064nm, 785nm+1064nm, 633nm+1064nm

Q: How to choose wavelengths of Raman Spectrometer?
266nm wavelength can differ the fluorescence signal from Raman signals so that it can be used to measure fluorescent materials
523nm wavelength is usually used to detect graphene, virus.
633nm wavelength is suitable for metallic oxide.
785nm wavelength can satisfy the general-purpose measurement
830nm wavelength is suitable for noninvasive blood glucose.
1064nm wavelength is suitable for the biological tissue, cell, bacteria, fuel, and high fluorescence samples.

Q: What's the application of a dual-band Raman spectrometer?
A: Scientific research, Bioscience, Forensic analysis , Material science research, Medical Immunology, Agricultural and food science, Wastewater analysis, Gemstone & inorganic minerals identification, Environmental science

Q: What is a portable dual-band Raman spectrometer used for?
A: The dual-band Raman spectrometer is used for application requiring two wavelengths. One wavelength can not satisfy the user's demands need to use dual-band Raman as a result.

Q: What does a portable dual-band Raman spectrometer tell you?
A: Dual-band Raman spectrometer can tell the manufacturer's mighty capabilities to provide one-stop solution to the non-expert user. It provides wavelength flexibility for customer's selection

Q: How much does a portable dual-band Raman spectrometer cost?
A: Optosky provides several dual-band Raman spectrometers that refer to a specific model for the inquiry.
ATR3200 Dual-band Raman spectrometer 
ATR8000 high-through portable dual-band spectrometer.
ATR8300 Dual-band Raman microscope
ATR8500 Dual-band Raman microscope
ATR8800 Scientific-grade Dual-band Raman microscope

Q: How does a portable dual-band Raman spectrometer work?
A: The Optosky self-designed dual-band Raman spectrometer is easy-to-operate with one scan button. The exclusive software of the Android platform designed for portable Raman spectrometer.

Q: How to choose a portable dual-band Raman spectrometer?
A: Firstly, select the wavelengths
     Secondly, which types of categories of dual-band Raman? such as portable dual-band spectrometer, dual-band Raman microscope, and high throughput auto-scan dual-band Raman spectrometer.
     Finally, select a reliable brand of Optosky that provides customization performance cost less.

Q: Where to buy a portable dual-band Raman spectrometer?
A: Distributor channels or contact manufacturer


Q: Why Optosky develop a high-throughput dual-band Raman spectrometer?
A: Optosky is developing high-throughput dual-band Raman spectrometer, because they can be used for a large number of samples autotest, eg: public security drugs, University, Lab and Scientific research, SERS Raman detect, and detect different samples or batches to identify the quality difference. They can be applied to industries of food safety, agriculture pesticide residues detection, biomedical…

Q: Why Choose Optosky's Dual-band Raman System?
A:
  • Optosky has been developing Raman spectrometer for 20-year.
  • Optosky is China National Standards drafter of Raman spectrometer
  • Top 1 in China brand and Top 3 brand in the world.
    In 2016 launch the first generation handheld Raman spectrometer,
  • In 2017 launch the dual-band Raman spectrometer
  • In 2020, launch the triple-band Raman microscope
  • In 2021, launch the quadriband scientific-grade Raman microscope
  • Optosky represents the highest performance cost less Chinese high-tech manufacturers with industry-leading warranty guarantee and technical support.
  • Optosky's Raman spectroscopy technology originate from Shanghai Institute of Technical Physics Chinese Academic of Science University and Xiamen University Zhong Qun Tian who discovers SHINERS makes SERS can be preserved longer than 2 years.
  • Quality control system follows Agilent Technologies
  • 60% R&D engineers  provide Industrial-leading warranty guarantee and technical support services
  • The most experienced engineers and 3 Drs team in Raman spectroscopy
  • Complete certification of ISO, CE, FDA Approval, Police Approval, API Approval

Q: Why the 1064nm Raman can resisit high fluorescence materials?
A: 1064nm belong to NIR photon has low frequency, low energy is seldom absorbed by the sample molecule, and it's difficult to excite ground state electron as well as fluorescence, so that it prevent fluorescence from generation.

Q: Why Raman signals are easily annihilated by fluorescence?
A: Fluorescence intensity is about 10^6 times stronger than that of raman signal. traditional Raman signals are easily annihilated by fluorescence.

Q: Which materials have high fluorescence recommended to use 1064nm Raman?
A: Such as Heroin, Fentanyl, Colour samples, Biological samples, Textiles, Bacteria, Drugs, Fuel, Petroleum samples, Vegetable oils, Explosives, Plastic.

Q:How many methods can remove fluorescence interference? 

1st, Baseline correction use algorithm to remove fluorescence interference.
2nd, Diference Raman use two wavelengths of lasers (eg: 784.5nm+785.5nm) to excite samples can obtain two sets of Raman signal and calculate the difference to obtian the spectrum without fluorescence.
3rd, Time gate control method
4th Florescence photobleaching method
5th, 1064nm Raman spectrometer is highly recommended

Q: What is the application of Raman spectrometer used in public safety?

A: When we still vividly remember the unpleasant memories happened in 2014 Xiamen city and a burned bus on which the passengers bringing the petrol along and bus burned suddenly killing many passengers. If the Raman spectrometer can be used to detect the explosives flammable and hazardous liquids on the entrance can avoid this accident. It takes few seconds to detect results, entrance and exit on the Metro, airport, BRT, bus, stadium, and large public places. And also government court, Police, Jail and fire fighting.

Q: What is the application of Raman spectrometer used in public safety?

A: In Jail, there are some criminals have potential intention of killing themselves. These criminals could find ways to bring in drugs, toxic substance inside jail. It’s needed to detect the presence of these toxic substance before entering jail. In court, there are some defendants who threatening to kill themselves to prove their own innocent. It’s necessary to use Raman spectrometer to detect the toxic substances before entering the court. The police arrest drug dealers and few criminal investigations and illegal factory check. Only the applications related to the drug enforcement administration, customs entry and exit, and police border defenses and fire brigade and court and jail. It’s known that fentanyl has many hundreds of variance and a Raman spectroscopy is very good tool to take fast take hundreds fentanyl variants to perform field criminal investigation on illegal factory check. Such as the 1064nm handheld Raman spectrometer can export good spectra of methamphetamine, Ketamine, Ephedrine. Etc.

Q: What is the application of handheld Raman analyzer used to identify gemstones?

 A: Handheld Raman analyzer, Portable Raman spectrometer, and Raman microscope are used to identify gemstones, Jade bracelet, diamond ring. Raman spectroscopy technology is the a great tool to identify true and take gemstones.

Q: What is the application of Raman spectrometer used in biomedical industry?

A: Raman Spectrometer is applied to biomedical industry, such as non invasive blood glucose.  The Samsung company announced the non invasive blood glucose wristband applied Raman spectroscopy technology. Apple company is researching on it. These two well-known companies had already developed the finished blood glucose wristband, say, non invasive blood glucose wristband have already made the industrialization possible. And the Raman spectrum can display different blood concentrations shown on a cell phone APP.

Q: What is the Raman spectrometer applied to detect cancer?

 A: In the published paper reviewed that the patients diagnosed cancer can be identified by Raman spectroscopy. The patient diagnosed cancer shows the peak in 751nm, and the healthy person shows the peak in 758nm, there are 7cm-1 shift and and this paper writer confer the accuracy is high. In addition, the Raman spectroscopy is applied to detect skin cancer. 

Q: How is the Raman spectroscopy technology is discovered?

A: There is a very interesting story told in 1920s, an Indian scientist named Raman discover why the sea is so blue, whose blue brighter than blue sky, and after his research, he finally found in 1928 that the sea has absorbed uv range and generated new blue lights. Raman write a paper of his discovery, in order to remember Raman scientist great discovery and people use his name to describe this phenomenon Raman Spectroscopy. The first Discovery of Raman spectroscopy in 1928. And in 1930s, Raman scientist has won the Nobel prize. In the scientists history, Raman spectroscopy has been a very big discovery.


Q: What is the Raman spectroscopy working principle?

A: When the molecule absorbs laser energy and generate energy level shift, but it is an unstable state. It can ring-down to the original energy level. If no energy shift part called Rayleigh scattering. However some part shift from E0 to E2, fall down to E1, This situation is called STOCKS, a single photon energy is lower energy & frequency than the laser energy but longer wavelength. The other part from E1 to higher energy level E1+hv0, and its ring down to E0 with the higher frequency and energy, but shorter wavelength called anti-stokes lines. In these situations still ring down to the deeper energy levels but less. Raman spectroscopy are mainly analyzing the STOKES lines.


Q: How is the Raman spectrometer work?

A: First of all, the narrow linewidth laser generates an excitation light go through the fiber and collimator mirror to form a parallel incident light, excitation light focus from here, and shoot on the sample to be detected. The sample absorbs excitation light energy and it happens the energy levels shift, then go through ring-down process of generating new Raman light with a 360 degree scattering.  Some portions of Raman scattering can be collected by our objective lens, then reflected from here, through long pass filter Rayleigh scattering, then couple into inside fiber and spectrometer. Raman spectrometer is used to analyze the collected Raman signal, wavelength, and intensity. Finally, it can get the Raman signal.


Q: How is the spectrometer work?

A: The CCD export signal going through circuit, DC power, and USB, then transfer on the PC software, and finally obtain spectrum result. 


Q: What is the application of Raman spectrometer?

A: 

1st, Biomedical industry of early cancer detection, ultrastructure change of biological molecule, calculi components analysis.

2nd, Public Safety of Drugs and Narcotics, Fast Detect Toxic Substance, explosives & Flammable materials, Drink water.

3rd, Environmental science of waste water contamination, petroleum analysis, deposits analysis.

4th, Pharmaceutical Engineer, Drugs scan and analysis, Crystallization in process monitor, Raw material QA & QC

5th, Food Safety, Detect refined gutter oil, Detect pesticides residues, Food additives and contaminants.

6th, Gemstones ID, Trace gemstones place-of-origin, Anti-counterfeiting, Antique ID

Q: What are differences between Infrared spectroscopy and Raman spectroscopy?

A: Infrared spectroscopy and Raman spectroscopy are twin brothers, their spectra are mutually complementary. 

1st, Working Principle Differences:

Infrared spectroscopy absorbs molecule absorption spectra, but the Raman spectroscopy absorbs the molecular emissions spectra with higher accuracy. It’s important to get a general idea that Raman spectroscopy technology is more accurate than Infrared spectroscopy.

2nd, Infrared spectroscopy is measured by contact, most infrared measurement requires sample preparation, but Raman spectroscopy requires no sample preparation and non-contact measurement through the glasses, plastic bags, kraft papers, and envelop etc.

3rd, Measure methods are different, infrared spectroscopy is destructive measurement can damage the sample requires larger samples quantities and consumable materials, but Raman spectroscopy is non-destructive measurement and can non-contact sample, no consumables materials. 

4th, Infrared spectroscopy requires sample preparation, but the Raman spectroscopy requires no sample preparation.

5th,Infrared spectroscopy measure molecular group, but Raman spectroscopy measure molecular skeleton with higher accuracy. 

6th,Tell the differences of isomer, including monomer isomeride, position 

7th, Infrared spectroscopy can not tell the difference of isomers, but the Raman spectroscopy can tell the difference of isomers, including monomer isomer, position isomers, geometric isomers, Fentanyl variants generated in varaints fast, and Raman spectrometer has positive advantage for Fentanyl detection.

8th, Infrared spectroscopy can not detect sample in water solution, which is easily influenced by the water, but Raman spectroscopy has little influence on water, even if the peak of  Another one is solutions. Infrared spectra is easily influenced by the water, but Raman can not be influenced by water am water has not raman signal, even at the peak of 3400 has a small curve, which have no influence on our measurement.

9th, Infrared spectroscopy is sensitive to water vapour, however, Raman spectroscopy can detect at any state anywhere.

10th, Infrared spectroscopy requires huge amount of samples to build up modeling, but it only takes 1-2mg sample to build a library.

More FAQ Click Me!