Availability: In Stock
NIR-II Fluorescence Microscope Imager
Product Code: ATF9280
Ask About This Product
application

Description

ATF9280 is a self-focusing and auto-scanning micro NIR-II microfluorescence imager carefully developed by optosky. NIR-II (1000nm to 1700 nm), tissue scattering is reduced and tissue absorption and autofluorescence are minimal. Compatible with traditional visible or infrared optical imaging (400nm-1000 nm), better image contrast, sensitivity and depth of tissue penetration at these wavelengths. It is especially suitable for small animal in vivo fluorescence imaging, real-time surgical navigation, etc.
ATF9280 has a built-in ultra-low temperature refrigeration high-sensitivity InGaAs detector that can be cooled down to -80°C.
ATF9280 is equipped with a 50X50mm large-area motorized scanning platform, supplemented by an advanced and fast ultra-large image stitching algorithm, so as to achieve the functions of fast scanning and large-area imaging.
ATF9280 is equipped with a highly stable autofocus system, which can adjust the dynamic focus of the target in real time to achieve the best imaging effect.
ATF9280 is connected to the computer through the USB 2.0 interface, and there is also advanced and easy-to-use PC-side control software, which can achieve perfect experimental operation.


Features

  • Wavelength:808、980、1064nm
  • Deep refrigeration InGaAs CCD:MInimum refrigeration temperature -80°
  • Imaging resolution: 640X512,1280X1024
  • Large area motorized scanning platform
  • Real-time auto focus, auto scan, auto stitching
  • The motorized control can continuously scan the fluorescence channel, continuously changing from 1000-1700nm, and the tuning accuracy is 5nm
  • Four-in-one optical fiber channel, which can connect four lasers at the same time, no need to switch light sources during multi-wavelength imaging
  • The laser light outlet is equipped with a beam expander to effectively increase the irradiation area of the excitation light
  • Powerful image acquisition and analysis software
  • The novel integrated frame provides excellent stability and operability
  • Modular structure design, multi-functional combination to ensure the versatility of the system

Tags: ATF

Parameters

ATF9280

ATF9280-HR

ATF9280-DC

Excitation parameters

excitation wavelength

808, 980, 1064nm, other excitation wavelengths can be customized

excitation light source

solid state laser

maximum excitation power

2.5W, 5W

Fluorescence receiving part parameters

Spectral detection range

900nm-1700 nm, continuously variable

Fluorescent channel selection

Electric control setting, continuous scanning or channel selection (4-20 channels)

Spectral channel adjustment resolution

1.0 nm

Imaging spectralre solution(FWHM)

5.0 nm

Detector

Cooled InGaAs CCD

Cooled InGaAs CCD

Deep cooling InGaAs CCD

Detector resolution

640X512

1280X1024

640X512

Refrigeration temperature

10℃

-10℃

-80℃

Integration time

1ms-20s

1ms-20s

15μs-5 minutes

Detector interface

 

USB 3.0

 

Dynamic Range

≥60dB

≥62dB

≥62dB

Maximum frame rate

120Hz

66Hz

100Hz

Visible light imaging system

light source

LED white light source

imaging camera

5 million pixel digital camera

camera port

USB2.0

Stage

Focusing device

Manual focus or automatic focus, and a focus upper limit device

Stage

Steel wire drive stage (X axis does not protrude), double clamp structure

Stage area

220X200mm

X, Y axis electric control two-dimensional platform

range of movement

50 X 50 mm ,100X100mm

mobile resolution

0.1  μm

positioning accuracy

1 μm

scanning speed

20mm/s

focus method

Manual, electric, real-time focus

Z axis (electric control, auto focus)

Focus accuracy

≤  ±0.2  μm

Maximum stroke

100 mm

focus speed

≤  10 s

Dimensions

890 X 610 X 520 mm

Weight

49.3 kg

Tags: ATF

    • Research Laboratory
    • (Small Animals, Etc.) In Vivo Fluorescence Imaging
    • Targeted Tumor Imaging
    • Microvascular Imaging, Monitoring Blood Flow Changes
    • Drug Targeting And Kinetic Studies
    • Real-Time Surgical Navigation 

    Tags: ATF

    Write a review

    Note: HTML is not translated!