Availability: In Stock
Single Flame Atomic Absorption Spectrometer
Download Data Sheet
Product Code: AS2000
Ask About This Product
application

The Single Flame Atomic Absorption Spectrophotometer (FAAS) AS2000 is a brand new product carefully crafted by Optosky. The original optical path design greatly improves the sensitivity in the ultraviolet region. The outstanding mechanical and optical system, coupled with excellent software, ensure the accuracy of measurement.


The economical single flame atomic absorption spectrophotometer AS2000 can install 4 hollow cathode lamps at the same time, providing 6 slits (automatic switching); the instrument has good stability, wide measurement range, low detection limit, high resolution and high sensitivity; The software adds a method storage function. Users can store the standard curve and call it up at any time, which can save analysis time and adapt to your pursuit of automated and accurate measurement results.

Tags: AAS
Atomic Absorption Spectrophotometer
Wavelength Range 190~900nm
Grating Line Density 1800 lines /mm
Absorbance Range 0–2.5ABS
Wavelength Repeatability ±0.1nm
Wavelength Accuracy Full spectrum ±0.2 nm
Optical System Integrated optical platform, fully enclosed optical system (single beam)
Detector Photomultiplier tube
Resolution Able to separate manganese doublet lines (279.5 and 279.8 nm) with a spectral bandwidth of 0.2 nm and a valley-to-peak energy ratio of <30%
Spectral Slits 0.1nm,0.2nm,0.4nm,1nm,1.2nm.2.0nm(automatically switchable)
Static Baseline Drift ≤0.004ABS/30min( Cu)
Lamp Holder 4-lamp turret
Characteristic Concentration ≤0.025ug/ml
Measurement Repeatability ≤0.5%(Cu,Absorbance>0.8ABS)
Detection Limit Cd ≤0.3pg
Gas Flow Control Needle valve control
Safety Protection Automatic gas cut-off for low pressure, power interruption, abnormal flameout, and burner mismatch
Background Subtraction Method Self-absorption background subtraction, deuterium lamp background subtraction
Burner Air-acetylene flame burner 100mm
Ignition Method Automatic ignition
Ignition Dynamic Baseline Drift ≤0.004ABS/30min(Cu)
Dimensions 700*500*530(mm)
Weight 80kg
Tags: AAS

  • HCL4 hollow cathode lamps (can be installed)
  • Safety control for abnormal situations, such as insufficient pressure, air leakage, flameout.
  • Provides 6 levels of slit (automatic switching)
  • The software adds a method storage function. Users can store the standard curve and call it up at any time, which can save analysis time.
  • Good stability, wide measurement range, low detection limit

Tags: AAS

  • Mineralsrare earth analysis and precious metals analysis
  • Environmental:Environmental Protection & Water quality testing
  • Material science:alloy materials & building materials
  • Scientific research: Elemental quantitative analysis in scientific research such as medical and health, and higher education institutions

Tags: AAS

Write a review

Note: HTML is not translated!