Flame Atomic Absorption Spectrophotometer
Availability: In Stock
Flame Atomic Absorption Spectrophotometer
Download Data Sheet
Product Code: AS2100
application
The single flame atomic absorption spectrophotometer AS2100 is a brand new product carefully built by Optosky. The flame sensor identifies the flame by sampling the flame temperature, eliminating the interference of external light on the sensor, and improving the reliability of flame identification; computer control completes automatic ignition. It ensures that ignition can only be carried out when safety conditions are met; when the flame is extinguished abnormally, it will automatically alarm and cut off the gas; the electronic gas circuit control of the flame gas flow will automatically alarm when the gas circuit pressure is insufficient.
AS2100 is compact in design and easy to operate. It provides safe, reliable and durable analysis methods for routine laboratory analysis, production process control and experimental teaching. It has excellent performance, accurate indicators and stable performance. It can meet many common needs and is deeply favored by users. favorite.
It is widely used in quantitative analysis of elements in rare earth analysis, precious metal analysis, environmental protection, water quality testing, alloy materials, building materials, medical and health, universities and other scientific fields.
Atomic Absorption Spectrophotometer | |
Wavelength Range | 190~900nm |
Grating Line Density | 1800 lines /mm |
Absorbance Range | -0.1~2.5ABS |
Wavelength Repeatability | ≤0.5nm |
Wavelength Accuracy | Full spectrum ±0.15 nm |
Optical System | Integrated optical platform, fully enclosed optical system (single beam) |
Detector | Photomultiplier tube |
Resolution | Able to separate manganese doublet lines (279.5 and 279.8 nm) with a spectral bandwidth of 0.2 nm and a valley-to-peak energy ratio of <30% |
Spectral Slits | 0.1nm,0.2nm,0.4nm,0.7nm,1.0nm.2.0nm(automatically switchable) |
Background Correction Technology | D2 background subtraction (background signal 1 ABS, background reduction capability ≥50 times) |
Static Baseline Drift | ≤0.002ABS/30min( Cu) |
Lamp Holder | Standard 6-lamp turret, optional 8-lamp turret |
Characteristic Concentration | ≤0.02ug/ml |
Measurement Repeatability | ≤0.5%(Cu,Absorbance>0.8ABS) |
Detection Limit | Cu≤0.004ug/ml |
Gas Flow Control | Needle valve control |
Safety Protection | Automatic gas cut-off for low pressure, power interruption, abnormal flameout, and burner mismatch; |
Background Subtraction Method | Self-absorbing background subtraction method |
Burner | Air-acetylene flame burner 100mm |
Nebulizer Chamber | Polypropylene coated |
Ignition Method | Automatic ignition |
Ignition Dynamic Baseline Drift | ≤0.003ABS/30min(Cu) |
Dimensions | 700*500*530(mm) |
Weight | 80kg |