Atomic Absorption Spectrophotometer
Availability: In Stock
Atomic Absorption Spectrophotometer
Product Code: AS2510
application
The AS2510 Flame-Graphite Furnace Integrated Atomic Absorption Spectrometer is a brand-new product elaborately developed by Optosky. It integrates flame, graphite furnace and hydride generation systems, and supports a variety of accessories. Flexible configuration options meet the demands of customers at different levels. Capable of analyzing complex samples, the AS2510 enables automatic switching among multiple analytical methods to realize unattended full-automatic analysis.
Widely applied in scientific research, quality inspection, CDC, environmental protection, metallurgy, agriculture-forestry, chemical industry and other fields, the AS2510 features innovative hardware and software design to guarantee accuracy, safety and user-friendliness for sample analysis, with simple and convenient instrument maintenance.
Equipped with a high-precision fully-automatic optical system, the spectrometer adopts a large-area grating with 1800 lines per millimeter and a novel auto-collimating monochromator. All optical lenses are coated with quartz film. The broad detection range and superior optical stability ensure analytical precision. Its fully-automatic eight-lamp holder is fitted with 8 independent lamp power supplies for separate preheating.
The AS2510 is equipped with highly-intelligent powerful software with a user-friendly Chinese interface. It supports full-automatic control of the instrument and peripherals, automatic optimization and automatic dilution. Operated via mouse, it can automatically set menu parameters and calibration methods, and realize dynamic display of measurement data.
The AS2510 Flame-Graphite Furnace Integrated Atomic Absorption Spectrometer is a brand-new product elaborately developed by Optosky. It integrates flame, graphite furnace and hydride generation systems, and supports a variety of accessories. Flexible configuration options meet the demands of customers at different levels. Capable of analyzing complex samples, the AS2510 enables automatic switching among multiple analytical methods to realize unattended full-automatic analysis.
Widely applied in scientific research, quality inspection, CDC, environmental protection, metallurgy, agriculture-forestry, chemical industry and other fields, the AS2510 features innovative hardware and software design to guarantee accuracy, safety and user-friendliness for sample analysis, with simple and convenient instrument maintenance.
Equipped with a high-precision fully-automatic optical system, the spectrometer adopts a large-area grating with 1800 lines per millimeter and a novel auto-collimating monochromator. All optical lenses are coated with quartz film. The broad detection range and superior optical stability ensure analytical precision. Its fully-automatic eight-lamp holder is fitted with 8 independent lamp power supplies for separate preheating.
The AS2510 is equipped with highly-intelligent powerful software with a user-friendly Chinese interface. It supports full-automatic control of the instrument and peripherals, automatic optimization and automatic dilution. Operated via mouse, it can automatically set menu parameters and calibration methods, and realize dynamic display of measurement data.
- High-precision fully-automatic optical system: 1800-line grating and novel auto-collimating monochromator. Wide detection range and excellent optical stability guarantee analytical accuracy.
- Eight-lamp holder: Fully-automatic 8-lamp holder equipped with 8 independent lamp power supplies for separate preheating.
- Full automation: Automatically completes safe ignition, flame-off and mode switching. Reliable structure with low failure rate ensures sensitivity and reproducibility for flame-mode measurement.
- Background correction system: Adopts deuterium hollow-cathode lamp and self-absorption background correction to eliminate molecular-absorption interference in low-level determination. When the deuterium-lamp background signal is 1 A, the background-rejection capacity is greater than 50-fold.
- Autosampler: Integrated with graphite furnace. Adopts high-precision syringe with minimum sample injection volume of 0.5 μL, featuring intelligent on-line dilution and concentration functions.
- High-precision fully-automatic optical system: 1800-line grating and novel auto-collimating monochromator. Wide detection range and excellent optical stability guarantee analytical accuracy.
- Eight-lamp holder: Fully-automatic 8-lamp holder equipped with 8 independent lamp power supplies for separate preheating.
- Full automation: Automatically completes safe ignition, flame-off and mode switching. Reliable structure with low failure rate ensures sensitivity and reproducibility for flame-mode measurement.
- Background correction system: Adopts deuterium hollow-cathode lamp and self-absorption background correction to eliminate molecular-absorption interference in low-level determination. When the deuterium-lamp background signal is 1 A, the background-rejection capacity is greater than 50-fold.
- Autosampler: Integrated with graphite furnace. Adopts high-precision syringe with minimum sample injection volume of 0.5 μL, featuring intelligent on-line dilution and concentration functions.