Availability: In Stock
Super FOV Fluorescence Microscopic
Product Code: ATF8100
Ask About This Product
This product has a minimum quantity of 1000
application

  • ATF8100 is a Auto-focus,Auto-scan Super FOV Fluorescence Microscopic designed by Optosky,two light sources are available,100W digital mercury lamp power supply and LED fluorescent light source. A third-order filter is used to filter the light source, and a six-hole turntable epi-fluorescence device (optionally with B, G, UV, and V filters) can be used to switch between different color filters to collect fluorescent signals in different wavelength bands.
  • The ATF8100 is TE-cooled down to -20℃, high sensitivity and high resolution spectrometer, which can perform spectral analysis on the target in the imaging area with a resolution of <2nm.
  • ATF8100 is loaded with 50X50mm large-area electric scanning platform,supplemented by advanced and fast super-large image stitching algorithms,  thus achieve the functions of rapid scanning and large-area imaging.
  • The ATF8100 is equipped with a highly stable autofocus system that can dynamically adjust the focal length of the target in real time to achieve the best imaging effect.
  • The ATF8100 is connected to the computer via a USB 2.0 interface, and has advanced and easy-to-use PC-side control software, which can achieve perfect experimental operation.

Tags: ATF
Detector
Detector type 2048 pixels CMOS
Sensitivity 1300 V/(lx·s)
Dark noise 0.4mV/RMS
Optical parameter
Signal-to-noise >800:1
Optical Design f/4 cross asymmetric C-T optical path
Raman Instrument
Integration time 1ms-60min
Spectral Range 300-1100nm, 200-400nm, 500-1100nm, 350-810nm Customzed
Resolution 1-2.5nm
Dynamic Range 10000:1
Focusing Electric, real-time focusing
Raman Spectrometer System Parameters
Interface SMA905
Epi-fluorescence system
Light source 100W digital mercury lamp power supply or LED fluorescent light source (choose one)
Six-hole tumtable epi-fluorescence device Standard three-channel switching: blue excitation B, green excitation G, purple
Excitation filter set Blue excitation wavelength:450~490nm Emission wavelength:515nm Green excitation wavelength:495~555nm Emission wavelength:595nm Violet excitation wavelength:380~415nm Emission wavelength:475nm (three channels)
Microscopic optical system
Optical system OTICS infinite distance chromatic aberration correction optical system
Magnification range 40X~1600X
Eyepiece 10X wide field of view, high eyespots flat field eyepiece,field of view Φ22mm (Φ23mm optional)
Infinite distant flat field achromatic objective lens Standard configuration 4X/10X/20X/40X (other optional)
Observation tube Hinged trinocular observation tube, tilted at 30°, interpupillary distance adjusted from 48mm to 76mm, three eyepieces and two gear shifts
Converter Internal tilt type internal positioning five-hole converter
Focusing device Coarse and micro coaxial focus adjustment, coarse adjustment belt elastic adjustment, and the focus of the upper limit device
Micrroscope stage Steel wire transmission stage (X axis does not protrude), double clip structure
Focusing mirror N.A.0.9/0.13 Swing-out focusing mirror,with variable light bar
Transmission lighting system 6V/30W Halogen lamp(Wide voltage input:100V~240V),Field light bar, adjustable center
Camera Equipped with 320/5 megapixels and other digital camera system for bright field shooting Equipped with 310/5.1 megapixel CCD digital camera for professional picture shooting
X,Y-axis electronic controlled platform
Moving Range 50 X 50 mm
Moving Resolution 0.1 μm
Positioning Accuracy 1 μm
Scan Speed 20mm/s
Z-axis(Auto-Focus)
Focus Accuracy ≤ ±0.2 μm
Max distance 20 mm
Focus Speed No more than 10 s
Dimensions 290 X 210 X 220 mm
Tags: ATF

  • TE-cooled down to -20℃, high sensitivity and high resolution spectrometer
  • Large area automatic scanning, automatic image splicing
  • Real-time autofocus
  • Powerful image acquisition and analysis software
  • Excellent infinity chromatic aberration correction optical system to ensure excellent resolution and clarity
  • Six-hole rotating disk fluorescence device, provides a variety of fluorescent excitation block selection
  • Five-hole turntable phase contrast device, equipped with 4X/10X/20X/40X/100X and other infinite flat field phase contrast objectives, can be used for phase contrast and bright field observation
  • Novel integrated frame provides excellent stability and operability
  • Modular structure design, multi-functional combination to ensure the versatility of the system
  • Large visual field eyepiece, field of view up to 23mm, more flat and comfortable observation
  • Two - shift three - eye observation tube,100% observation; 20% observation, 80% photography at the same time

Tags: ATF

  • Research Lab
  • Hospital and Biochemical Lab
  • Hospital Clinical Test
  • University Teaching

Tags: ATF

Write a review

Note: HTML is not translated!