Description
The Optosky UV3610 is a UV-Visible-NIR Spectrophotometer that acquires spectral signals from 185-3300 nm. It features high-sensitivity detectors: PMT, InGaAs, and PbS, covering 185-900 nm, 900-1700 nm, and 1700-3300 nm respectively, achieving optimal sensitivity and signal-to-noise ratio.
The UV3610 provides precise transmission and reflectance measurements across the UV to near-infrared regions, significantly enhancing sensitivity.
The instrument uses a high-power 50W halogen lamp and a socket-type deuterium lamp, ensuring excellent measurement results and easy replacement. The UV3610's unique wavelength control system enhances accuracy with various bandwidth options, ensuring low noise and a wide wavelength range. The high-performance light source ensures stable light intensity.
The UV-Vis-NIR spectrophotometer’s software is fully designed in English, offering a clean, user-friendly interface with functions for spectral scanning, photometric measurements, time scanning, kinetics measurements, data transmission, storage, and printing.
The UV3610 is versatile for environmental analysis, pharmaceutical analysis, chemical analysis, food quality testing, and water quality testing.
Features
- Measurement Range: 185-3300 nm;
- Low Stray Light Optical Design;
- Three Detectors;
- Automatic Six-Cell System;
- Light Source: 50W halogen lamp and deuterium lamp (socket type)
- User Interface: Simple and intuitive operation page;
- High-Speed Data Acquisition;
- USB Data Output Interface;
- Three-Color Indicator Lights;
- Superior Optical System;
Model | UV3610 | UV3610-TP |
Wavelength Range | 185~3300 nm | |
Optical System | Dual Beam | |
Sample Cell Channels | 6 channels, auto-switching | |
Spectral Bandwidth | UV/Vis: 0.1, 0.2, 0.5, 1, 2, 3, 5, 8 nm (8 steps) | |
Wavelength Accuracy | UV/Visible: ±0.2 nm | |
Wavelength Repeatability | UV/Visible: ±0.08 nm | |
Photometric Accuracy | ±0.003 Abs (1 Abs) | |
Photometric Repeatability | ±0.0016 Abs (0.5-1.0 Abs) | |
Drift | <0.0002 Abs/h (2 hours after power-on at 500 nm, 1-second integration) | |
Stray Light | <0.005% T | |
Noise | <0.00005 Abs RMS (500 nm) | |
Photometric Modes | Absorbance (Abs), Transmittance (%), Reflectance, Energy (E) | |
Resolution | 1 nm | |
Wavelength Adjustment | Automatic scanning | |
Baseline Flatness | ±0.004 Abs (185-200 nm) | |
Photometric Range | -6 to 6 Abs | |
Baseline Correction | Computer automatic correction (baseline stored at power-on, can be recalibrated) | |
Detectors | PMT, InGaAs, PbS | |
Light Source | 50W halogen lamp and deuterium lamp (socket type) | |
Display | None | 7-inch capacitive touchscreen |
Internal Storage | None | 32GB storage, can store 1 million spectra |
External Interface | USB 2.0 | USB 2.0, LAN, WIFI |
- Research in Scientific Institutes
- Biological Sciences
- Medical Analysis
- Agriculture and Food Testing
- Environmental Science
- Water Quality Analysis
- Textile Industry
Type | UV-VIS-NIR Spectrophotometer | |
Model | UV3600 | UV3610 |
Wavelength Range | 185-1700nm | |
Measurement Method | Double Beam | |
Wavelength Accuracy | UV, VIS:±0.08nm NIR:±0.4nm | UV, VIS:±0.2nm NIR:±0.8nm |
Wavelength Repeatability | UV, VIS:±0.08nm NIR:±0.32nm | UV:±0.08nm NIR:±0.35nm |
Spectral Bandwidth | UV/Vis: 0.01~ 5nm, 0.01nm Automated adjustable | UV/Vis:0.1, 0.2, 0.5, 1, 2, 3, 5, 8nm 8-bands transformation |
Measurement Accuracy | ±0.3%(0-100%) | ±0.003Abs(1Abs) |
Transmittance Repeatability | ±0.15%(0-100%) | ±0.0016Abs(0.5~1.0Abs) |
Absorbance Range | -8-8A | -6-6A |
Stability | < 0.0002Abs/h (light source light up 2 hour later500nm) | |
Stray Light | < 0.00008%T (220nm,NaI 10g/L solution) | < 0.005%T |
Wavelength Drive | Automated | |
Display | / | |
Detector | PMT | |
Light Source | 50W Halogen and Deuterium lamp (socket type) | |
Measurement Type | Transimittance, Absorbance, Concentration, Energy | |
Noise | 0.00005A RMS(500nm) | |
Baseline Flatness | ±0.004A(185-200nm) |