Super-high resolution Spectrometer
Super-high resolution Spectrometer
5
7
Availability: In Stock
Super-high resolution Spectrometer
Product Code: ATL30007
application
With 20 years of experience in developing optical fiber spectrometer, Optosky launched a new generation of high-performance ultra-thin optical spectrometer: AT L30007 has 5 ultra-high-resolution optical spectrometers, each adopts a high sensitivity linear CMOS, of 4096 pixels and specially customized ultra-low noise CMOS signal processing circuit, which greatly reduces sensor noise, obtains excellent signal-to-noise ratio (about 2 times higher than similar competitors), and improves ATL30007 measurement reliability without the ambient temperature, the best level in the industry.
The AT L30007 can receive the SMA905 fiber input light or free space light and output the measured spectral data via the USB2.0 or UART port.
AT L30007 only requires a 12V DC power or USB power, very easy to integrate.
Detector | |
Detector type | Linear ray CMOS |
Effective pixels | 4096*5 |
Pixels dimension | 7 x 200 µm |
Sensitivity | 1300 V/lx*s |
Dark noise | 0.4 mVrms |
Optical parameter | |
Optical resolution | 0.1-0.16 nm (Depend on the slit, spectral range) |
Incident Interface | SMA905 fiber interface or free space |
Signal-to-noise | >450:1 |
Dynamic range | 3000:1 |
Working humidity | < 90%RH(No dew) |
Full Well | 200 ke- |
Wavelength range | 200-920 nm(depending on demand) |
Physical parameters | |
Dimensions | 39.5 x 24.5 x 19 cm |
Weight | 2.5kg |
Optical configuration | |
Optical design | f/4 crossed CT |
Incident slit | 5, 10 μm optional or customized |
Electrical parameter | |
A/D conversion resolution | 16bit |
Integration time | 0.1 ms - 130 s |
Interface | USB 2.0 or UART |
Supply voltage | DC 12 V (type @12V) |
Operating current | 3A(@Typ) |
Storage temperature | -30°C to +70°C |
Operating temperature | -25-50°C |
- Detector: Linear CMOS
- Probe pixels:
- 4096 × 5 pixels (built-in 5 spectrometers)
- Ultra-low-noise CCD signal processing circuit
- Maximum spectral range: 200-920nm (depending on demand)
- Spectral resolution: 0.1-0.16 nm (depending on the spectral range, slit width)
- Optical path structure: Cross C-T
- Integration time: 1ms-130s
- Power supply: DC 12V±10%
- Digital bit depth: 16 bit
- Optical input interface: SMA905
- Data output interface: USB2.0.
- The LIBS, Plasma emits light
- Laser wavelength measurement
- Spectral analysis / radiative spectroscopic analysis / spectrophotometric analysis
- Controlled thermonuclear fusion
- Low-pressure plasma spectroscopy detection
- Dielectric blocking discharge plasma
- spectroscopy detection
- Plasma processing process analysis