The ATR3180 super fast line scan Raman spectroscopic imager is a brand-new, optimized and designed macro Raman spectrometer with breakthrough features developed by Optosky in 3 years for more than 20 years in the development of Raman spectrometers. It uses ultra-high-power laser, linear laser shaping technology, spatial resolution spectrum analyzer, and ultra-low temperature refrigeration (-70°C) high-sensitivity area array CCD, allowing the instrument to scan and image large-area samples ultra-fast. ATR3180 can adapt to use in complex environments. The Raman spectrometer has a wide range of applications, especially in the fields of scientific research, food safety, pharmaceutical engineering, new materials, new energy, etc.
The multifunctional software shipped with the ATR3180 has been rigorously tested by hundreds of scientists around the world and collected their improvement opinions. It has been updated in nearly a hundred versions. Its functions are very complete and stable, and it is very suitable for the development of Raman research work.
Model | Excitation wavelength | Maximum laser power |
ATR3180-473 | 473nm | 5W |
ATR3180-532 | 532nm | 30W |
ATR3180-638 | 638nm | 5W |
ATR3180-785 | 785nm | 30W |
▪Tested according to the American national standard ASTM E2529-06 method.
▪The above parameters only represent the company's standard products, other parameters can be customized.
▪If specially customized, the resolution performance can be improved by about 1/3, but the sensitivity will be sacrificed.
Detector | |
Detection range | 200-1100nm |
Full well capacity | 300 Ke |
Optical parameter | |
Number of spatial bands | 512 (single scan), 100,000 (Z-shaped scan stitching) |
Number of spectral bands | 2048 |
Scan displacement platform | |
Scanning method | Electric |
Maximum moving range (length, width) | 800×600 mm (customizable) |
Raman Instrument | |
Focusing | 98 mm for incidence and output |
Raman Spectrometer System Parameters | |
Interface | USB 3.0 |
Integration time | 8ms-61.3hours |
Operating temperature | 10 - 35 ℃ |
Operating Humidity | < 90% |
Dimension | 450x330x132mm |
Weight | 14.5 Kg |
Raman spectrometer Relibility | |
Spectral Stability | σ/μ<0.5% (COT8hours) |
Temperature Stability | Spectral shift≤2 cm-1 (10-40℃) |
Spectral Range Change Stability | <±2% (in 5 ~ 40℃) |
Raman Spectrometer Optical Parameters | |
Resolution | 2.0 cm-1 |
SNR | >8000:1 |
Sensitivity | QE>85%, 6.5 μV/e- |
Raman spectrometer Detector | |
Detector Model | Ultra-low temperature refrigeration, ultra-high sensitivity area array CCD |
Cooled down to | -70℃ |
Effective Pixels | 2048*264 pixels |
Dynamic range | 50000:1 |
Pixel Size | 14μm×14μm |
Raman Spectrometer Laser Parameters | |
Laser power | Each excitation wavelength is not consistent |
Laser Linewidth | 0.1 nm |
Power Stability | σ/μ<±0.2% |
Raman probe | |
Cooling method | Water cooling |
Excitation divergence angle | 23° |
Maximum moving range (height) | 800 mm (customizable) |
Raman Spectrometer Probe | |
Operating Distance | <1.0 m |
Rayleigh Scatter Resistance | OD>8 |
Electrical parameter | |
Power voltage | DC 12V(+/-5%) |
lLine scan Raman imaging, super fast scanning imaging
lSpatial resolution up to 512 bands (single scan)
lUltra-low temperature refrigeration, ultra-high sensitivity detector
lThe sensor is cooled to -70 ℃
lUltra low noise circuit
lPowerful PC-side spectral analysis software
lAdvanced spectral processing algorithms and software
lFriendly human-computer interface
lNanoparticles and new materials
lResearch institute research
lBiology
lForensic Medicine Identification
lMaterial science
lMedical Immunoassay
lAgriculture and food identification
lGem and inorganic mineral identification
lEnvironmental science