Availability: In Stock
Best FieldSpec Spectradiometer
Download Data Sheet
Product Code: ATP9110

Qty

Request a Quote or Info
application

ATP9110 series broadband field spectroradiometer is a new portable hyperspectral fieldSpec from Optosky. Wavelength range of 300-2500 nm, suitable for geological research, mineral exploration, remote sensing, crop monitoring, forest research, oceanography and other fields of application. 

ATP9110 field spectroradiometer employs high performance, fast and accurate measurement, easy to operate and held etc. It's configured powerful software package, and applied to measurement of reflectance, radiometry, photometry and colorimetry. 

Order Guides

ModelDescription
ATP9110-25
Standard resolution 300-2500nm FieldSpec,@ 0.8-1.4 nm@756 nm, 7-12 nm @1400&2100 nm.
ATP9110H-25High resolution 300-2500nm FieldSpec, @ 0.8-1.4 nm@756 nm, 5-8 nm @1400&2100 nm
ATP9110-17High resolution 300-1700nm FieldSpec,@ 0.8-1.4 nm@756 nm, 7-12 nm @1400 nm
ATP9110-50300-5000nm Ultra wide band FieldSpec, @ 0.8-1.4 nm@756 nm, 7-12 nm @1400&2100 nm, 30 nm @ 2.5-5 um
ATP9110-110

300-11μm Ultra wide band FieldSpec (Without 5-5.5μm), @ 0.8-1.4 nm@756 nm, 7-12 nm @1400&2100 nm, 30 nm @ 2.5-5 um, 50 nm @5.5-11 um

Same Series Order Guides


Detector
Detector type Linear CMOS detector / InGaAs detector / Poryelectric linear CCD
Detector model 300-1100 nm CM0S 2048 pixels 1100-1700 nm InGaAs TE 2nd class cooling 1100-2500 nm InGaAs TE 2nd class cooling 2.5-11 um Poryelectric linear array CCD
field spectroradiometer
Spectral Range 300-1700 nm 300-2500 nm 300-5000 nm 300-11000 nm
Spectral Resolution 0.8-1.4nm@756nm 8-12 nm or 5-8 nm @1400&2100nm 30 nm @ 2.5-5.5 um 50 nm @ 5.5-11 um
Spectral sampling (bandwidth) 0.4nm
Maximum radiance VNIR 2 times sun light/SWIR 10 times sun light
Integration time 1 – 10 s/ auto optimized integration time
Input 1.5m fiber beam (25°FOV),optional front camera change FOV, optional fiber lengths.
Battery >3H(outdoor), Battery replaceable
SNR 300-1000 nm >800 , 1000-2500 nm> 16000
wavelength accuracy ± 0.1nm@ VIS ± 0.5nm @ SWIR ±3nm @ MWIR
Wavelength reproducibility ± 0.1nm
Electrical parameter
Interface TYPE-C3.0 /USB 3.0, blue/ wireless
Operating current 2500mA
Storage temperature -20°C ~ +65°C
Operating temperature -20 ~ 50 oC
Raman spectrometer Detector
Detector Power Supply Built-in Li battery 10000maH, optional external 12V power supply/ car loaded power supply
Physical parameters
Dimension ATP9110-17 : 290×260×141 mm ATP9110-25 : 350×300×170 mm ATP9110H-25 : 290×260×141 mm ATP9110-50 : 290x260x141 mm ATP9110-110: 350x300x170mm
Weight 4.5- 6.5 Kg
Raman Spectrometer Laser Parameters
Laser Linewidth 650 nm
Laser Output 5 mW
  • Broad spectrarange: 300nm-11um, ATP9110 has an ultra-wide wavelength range, this is Optosky's unique technology;
  • High sensitivity, detector quantum efficiency reach up to 60%, NIR sensitivity is 40% higher than traditional PDA detector;
  • Fast measure speed, one sampling time< 10ms, faster than ASD field spec.
  • Light weight and flexible optic fiber probe; 
  • Built-in secondary diffraction coating and filter, high accuracy;
  • Dynamic dark current correction, reduce noise;
  • Display probe inclined angles, laser indicator indicates probe direction, easy to adjust;
  • Portable, speciacarrying case, easy to carry;
  • PC software contromode, the two software work together to make data calculation more accurate.

Accessories Lists

StandardAccessories

USB wires & Suitcase

FOV angles, optional 1º/5º/8º/10º/15°/25°

Outdoor fiber

Leave clip, vegetation reflectance measure tool
Exclusive PC software
Indoor lighting

Charging adaptor 12V/5A

Halogen lamp accessories/ATG1021  INT:12V

Cosine angle lens

Measure test stand + integration sphere measure transmittance tool
External battery pack 14.4V
Standard white plate 10 x 10cm; 99% reflectivity (Customized)
External battery pack charger
Standard white plate 10 x 10cm; 60% reflectivity (Customized)

Field Angle lens 25°


Standard white plate 10 x 10cm; 95% reflectivity


  • Geologica research, prospecting
    ATP9110 systems support researchers to study the material composition, internal structure, external characteristics, interactions between layers of the earth, and evolution history. The main research object is the solid crust of the earth---crust or lithosphere. Help their work more easier.
  • Remote sensing measurement
    Remote sensing is the process of detecting and monitoring the physical characteristics of an area by measuring its reflected and emitted radiation at a distance (typically from satellite or aircraft).  Optosky has the advanced technology and can bring customers the best experience.
  • Crop monitoring
    The ability to accurately perform reflectance and radiometric measurements of crop and soil in the field is critical to understanding light utilization and partitioning within a plant community. 
  • Forest research, oceanographic research
    ATP9110 systems are used to determine plant physiological status, including disease status, nutritional status related to nitrogen uptake and moisture balance.\


Q: What is the wavelength range?

A: ATP9110 is available in 300-2500nm. 

Q: What is the wavelength repeatability?

A: The sensitivity of ATP9110 is ± 0.1nm@ VIS; ± 0.5nm @ SWIR; ±3nm @ MWIR.

Q: What is the wavelength Accuracy?

A: Wavelength Accuracy of ATP9110 is ± 0.5nm @ VIS; ±1.1nm @SWIR; ± 5nm @ MWIR.

Q: What is the size?

A: It's 290×260×141mm.

Q: What is the weight?

A: The weight is about 4.5Kg.

Q: What is the ATP9110 miniature spectrometer?

A: The ATP9110 is ideal for geological research, mineral exploration, remote sensing, crop monitoring, forest research, oceanography and other fields of application. You can configure spectrometers for different applications depending on your requirements. Spectral ranges from 300 nm Up to 2500nm, the spectral resolution can be selected from 0.8-1.4nm @ 756nm; 7-12nm @ 1400&2100nm; 30nm @ 2.5-5um.

Q: What is ATP9110 used for?

A: The ATP9110 can be adapted to geological research, mineral exploration, remote sensing, crop monitoring, forest research, oceanography and so on.

Q: How much does an ATP9110 cost?

A: USD75,900/unit, customers contact Optosky sales for more price details

Q: How long is the spectrometer warranty?

A:  one-year warranty.

Q: Where to buy ATP9110?

A: Optosky ATP9110 is in-stock, contact sales for more details.


More FAQ Click Me!

Write a review

Note: HTML is not translated!