Cavity Blackbody
Availability: In Stock
Cavity Blackbody
application
The ATG8000 medium-temp cavity blackbody complies with GBT 19870-2018 industrial detection infrared thermal imagers and JJF 1187-2008 thermal imager calibration specifications, providing a set of reliable medium-temperature cavity blackbody radiation sources for scientific research and industry.
ATG8000 cavity blackbody has a temperature resolution of 0.01°C, a temperature stability of 0.01°C/30min (ATG8000-T660), ±0.5°C (ATG8000-T1000), and an emissivity of 0.99±0.01. The characteristics of high resolution and high stability make it very suitable for calibrating various radiation thermometers, such as non-contact infrared thermometers, optical thermometers, etc.
The emissivity of ATG8000 is as high as 0.99±0.01. The ultra-high emissivity is very useful as a light source to measure the surface emissivity of materials.
The ATG8000 cavity blackbody can communicate via RS485, Ethernet, and Wi-Fi. When paired with the Optosky blackbody controller, it can achieve high-precision temperature control.
Optical parameter | |
Working temperature | 0 to 50 °C |
parameter | |
Aperture size | 0.8, 1.6, 3.2, 6.4, 9.5, 12.7, 15.9, 22.2 mm |
Built-in temperature sensor | ATG8000-T660: Pt100 ATG8000-T1000: S type thermocouple |
Caliber | 1 inch |
Effective emissivity | 0.99 ± 0.01 |
Radiator type | Cavity type |
Standard calibration method | Front temperature sensor/standard transmission radiometer |
Temperature accuracy | ATG8000-T660: Ta+5℃~<450℃ is ±(0.15+0.002 x |T|), 450℃~660℃ is 450℃~660℃ ATG8000-T1000: ±2 °C |
Temperature control and calibration software | BMC-30 |
Temperature range | ATG8000-T660: Ta+5℃~660℃ ATG8000-T1000: Ta+5℃~1000℃ |
Temperature resolution | 0.01℃ |
Temperature stability | ATG8000-T660: 0.01℃/30min ATG8000-T1000: ±0.5℃ |
Way of communication | RS485、Ethernet、WIFI |
Weight | 7kg (radiator) + 3kg (controller) |
- Temperature range: Ta +5℃~660℃/1000℃.
- High temperature resolution: 0.01℃.
- High stability: 0.01℃/30min, ±0.5 °C.
- Blackbody emissivity: 0.99 ± 0.01.
- Various aperture sizes available.
- Professional temperature control and calibration software.
- Multiple communication methods: RS485, Ethernet, WiFi.
- Radiation thermometer calibration
- Infrared thermal imaging camera calibration
- Calibrate the radiation intensity of the infrared radiation source
- Calibrated response rate for radiation absorption
- Study the thermal radiation properties of material surfaces
- Measure material surface emissivity