Optosky ATX2000 is newly designed high-performance, low-noise absorbance & fluorescence measuring system. It consists of long lifetime pulsed Xeron lamp, low noise optic fiber spectrometer, absorbance & fluorescence multi-functional measuring sample cell, optic fiber, collimating system etc. Low noise optic fiber spectrometer employs optimized designs in phonology, electronics, which greatly reduces sensor noise to obtain optimized SNR(about 5 times higher than other competitors). Measuring reliability has been greatly improved, so measuring results do not change with ambient temperature.
ATX2000 simple configuration can be used to research and measure various spectrum such as reflectance, transmission, absorption, fluorescence etc.
ATX2000 employs pulsed Xenon lamp lifetime>109 (wavelength range: 190-1100nm),usually it' not required to replace light source > 5 years.
ATX2000 requires only 5V DC power supply and PC to start to work, easy to operate.
Multi-function measurement such as absorbance & fluorescence measurement
Wavelength range:190-1100nm
Absorbance reach up to 3.2
Require no preheating, directly operate with electricity
replaceable fluorescence filter
Ultra-low CCD signal process PCB
Spectral resolution: 1.6 nm
Optical path: crossed C-T
Measuring time:2ms-130s (software setup)
Spectrometer controls light source, synchronized measurement
Power supply:DC 5V±10% @ <2.3A
Light input connector:SMA905 or free space
Output data interface:USB2.0 (High speed) or UART
20-pins dual-row programmable extension connector
ATX2000 Low noise absorbance & fluorescence measuring plan | ||
Spectral range | 190-1100 nm | |
Resolution | 1.6 nm | |
Absorbance measuring range | 0-3.2 | |
Entrance connector | SMA905 connector | |
Optic fiber length | >1.5m | |
Optical aperture | Ø5mm | |
Optical path | 10mm | |
Operating temp | -10-45 oC | |
Operating humidity | < 90%RH | |
Spectrometer | ||
Type | Low noise Linear sensor | |
spectral range | 190-1100 nm | |
Effective pixels | 2048 | |
Pixel size | 200μm×14μm | |
Optical resolution | 1.6 nm | |
SNR | >2300:1 | |
Dynamic range | 8000:1 | |
Optical path | f/4 crossed C-T | |
Confocal length | 40 mm for incidence / 60 mm for output | |
Electrical parameters | ||
Integration time | 1 ms - 130 second, software setup | |
Output data interface | USB 2.0 | |
ADC bit depth | 16 bit | |
Power supply | DC 5V±10% | |
Operating current | <2.3A | |
Storage temp | -20°C to +70°C | |
Operating temp | -10°C to +45°C | |
Pulsed Xenon lamp | ||
lifetime | ≥109 | |
Broad spectrum | 185nm-2000nm | |
Preheating time | Required no preheating, start immediately | |
Power | 5W |
Lab in university,institute etc.
Multi-parameters online water quality analyzer
Small volume, fast spectrophotometer
Spectral analyzer, spectroradiometer, Spectrophotometer analyzer
Fluorescence spectrometer
Biochemical analyzer
Transmission, absorbance measurement
Reflectance measurement