Availability: In Stock
Hyperspectral Imaging Microscope (400-1000nm)
Product Code: ATH5010

Qty

Request a Quote or Info
application

Description:

OPTOSKY@ ATH5010,ATH5011,ATH5020 is launched for hyperspectral imaging microscope with a feature of compact size, high-definition, high-quality. The structure consist of high magnification microscope, hyperspectral imaging camera, and data processing workstation, etc.

  ATH5010,ATH5011,ATH5020 employs 1920X1080 pixels CCD imaging element, clear image, low noise, internally embedded unique image compression algorithm with high compression rate, improve storage life span longer than 3hrs in order to satisfy drone requirement;

 ATH5010,ATH5011,ATH5020 spectroscopy imaging technology make spectral image has fast, accurate, high resolution, high spatial resolution, and high universality, etc. It can used to research medical, pathology, pharmaceutical, and life science, and more, in the institutes of medical, scientific, medical colleague, and pharmaceutical company. 

  • What is the Principle of Medical Microspectroscopy?

    It provides principle graph of medical microspectroscopy, object in the operation table through objective lens and microscopic sets dividing three paths: one path is observed by surgery naked eyes; the second is observed by the assistant for the supplementary; the third received from imaging spectrometer to perform spatial scan function via motor driving, and obtain the imaging spectral information, then data analysis and image processing, display to doctors via screen.

  • What is the Hyperspectral Imaging Spectroscopy module?

Spectral Range
     400-1000nm
Resolution
    Superior to 3nm
Spatial Resolution
   Superior to 2mrad
Spectral Channels   
270 (Max. 1280)
Spatial Channels
480(Max. 1920)
Pixel Size
7.8mm×14.2mm
NA
F/2.4
Bit
12bit
FOV overlap
Inclination less than 10% diameter of FOV
Cleanliness
FOV no obvious defects of mottling, scratch, air bubbles, etc. No obvious broken edge, greasy dirt, and attachments etc.
Inclination Degree
Proper wok within 10°
Stability
Bracket stability, stationary motion, firm positioning in motion
Operating Voltage
100~220V ±10%
Electromagnetic Compatibility
Electromagnetic Compatibility test can pass general and safety performance requirement


  • What is Microscope configuration?

Optical System
Infinite corrected optical system/Normal corrected optical system
Reviewing head
Binocular or Trincular,30° inclination,Pupil distance 50-75mm
Eyepiece
Two pieces of high point eyepiece plane ocular lens PL10X/22mm,PL20X/12mm,FOV adjustable, ±5 diopter,ocular cone Φ30mm
Optical magnification
40~2000 magnification(total 8 revolving nosepieces)
Objective Lens
Infinite plan achromatic objective:  4X,10X,40X,100X, optional
Revolver
Inner 4/5 holes
Condenser
Abbe condenser(available in attaching phase contrast,dark field, polarized light attachment interface)
Stage
220×148mm, double-layer X-axis wire transmission mechanical motion platform, travel: 76X50mm; accuracy: 0.1mm
Focusing
Fine focusing 0.002mm
Lightening
3W LED Lighting continuous adjustable Köhler illumination
Digital Imaging
5-mega pixels,HD digital USB port,clear image,smooth picture, connect PC to take image or camera, video, measurement, edit, save and print.



  • What is Packing List?

 P/N
Descritpion
Qty  
 configuration
1
Hyperspectral imaging microscopy
 (400-1000nm)
1 set
  standard
2
Objective lens and radiance calibration
1 set
  standard
3
Hyperspectral imaging service workstation(operating controller and software)
1 set
  standard
4
Halogen light source
4 set 
  standard
5
Standard calibration board
1 pcs 
  standard



Features:

Range:400-1000nm

Hyperspectral resolution:<2.6 nm or 4nm(ATP9020)

Broad FOV:23.5°@f=35mm(in relation to lens)

Instantons FOV:0.9 mrad@f=35mm(in relation to lens)

Samples’RGB picture processing and analysis 

HD Camera

HB LED

Applications:

Medical Institute, Cancer Tissue Sorting, Blood Cell Classification;

Scientific Research Institute

Medical Universities

Pharmaceutical company: herbal materials identification

Food safety: meat source identification; 

Microplastics identification

Mineral materials screening

Diamond colors identification

What's differences between ATH5010, ATH5011,  and ATH5020?

ATH5010 Specification:

Mounting platform:  Inverted Microscope

Spectral Range:  400-1000nm

Spectral Resolution:  2.2nm

Stage with HD 2D scan

Industrial CCD Camera

ATH5011 Specification:

Mounting platformInverted Microscope

Spectral Range400-1000nm

Spectral Resolution2.2nm

Stage with HD 2D scan

Scientific-class CCD Camera (High SNR & sensitivity, and high resolution)

ATH5020 Specification:

Mounting platform:  Upright Microscope

Spectral Range:  400-1000nm

Spectral Resolution:  2.2nm

Stage with HD 2D scan

Industrial CCD Camera

Write a review