Availability: In Stock
532nm Portable Raman Spectrometer
Product Code: ATR3110-532nm

Qty

Request a Quote or Info
application

ATR3110-532nm portable Raman instrument fit to fieldwork. With high reliable measuring accuracy, excellent low stray light, it enables a wide range of application, especially in industries of the biochemical analyzer, public safety, food safety, pharmaceutical engineering etc. The multi-function software realizes the application of the spectral analysis process. The remote experiment access to internet improves efficiency.


ATR3110-532nm built-in interface enables users both technical & non-technical work freely. The high-quality hardware configuration and robust multivariate algorithms provide the accurate, uniform and reliable detect result.


Optosky 532nm portable Raman is an ideal instrument for detect graphene, Xiamen University test our parameters and they approve our system high-performance, high-sensitivity, and high resolution.
Detector
Spectral range 200-2800
Pixels dimension 2048×64 pixels
Detector model S11850
Raman Instrument
Integration time 1ms-30m
Resolution 12
Dimension 26×33×16.5cm^3
Weight 8kg
Pixel Size 14×14 μm
Size 120μm
Dynamic Range 50000:1
Interface USB
Laser Output 100mW / 80mW at probe
Operating Temperature -10-40℃
system parameter
Humidity Range 90%
Handheld Raman sets
Detector CCD
Optical parameter
Working humidity 6
Trigger NO( Trigger on proble YES/NO)
Cooling temperature -5℃
Electrical parameter
Storage temperature -30 -70℃
Raman probe
Wavelength 532nm

ATR3110 -532 System

Interface

USB 2.0

Integration time

1ms - 120s

Power voltage

DC 5V(+/-5%)

Operating Temp

-10~40

Operating humidity

< 95%

Dimension(L*W*H)

30×22.5×13.2 cm3

Weight

7 Kg

Reliability

Spectral stability

σ/μ < 0.5%  (COT 8 hours)

Temp stability

Spectral shift 1 cm-1 (10-40 )

Variation of intensity

in 5 ~ 40 ℃)

<±5%

Optical parameters

Spectral range (cm-1)

200-3700

 

 

resolution (cm-1)

8

 

 

SNR

>1500:1

Entrance slit

f/4  C-T crossed optical path

Optical system

98 mm for incidence and output

Detector

Item

Ultra-high sensitivity, quick cooled-CCD

Temp cooled down to

-10

Detector range

200-1100 nm

Effective pixels

2048*64

Dynamic range

500001

Pixel size

14 ×200 μm

Exciting Laser

Central wavelength

532nm (+/-0.5nm)

FWHM

0.1 nm

Power output

100 mW

Power stability

σ/μ <±0.5%

Raman probe

Operating distance

6 mm

Rayleigh scattering resistance

OD>8

Numerical Aperture

0.3

Aperture

7mm


Features:

Ultra-high sensitivity FFT-CCD TE-cooled; 

low noise circuit;

High stable narrow band laser; 

Powerful embedded software;

Fluorescent background eliminate; 

Peak finding and displaying;

User-friendly human-machine interface;

USB 2.0 port

Application:

Bioscience

Material science

Pharmaceutical engineering

Forensic analysis

Agriculture and food safety

Gemstones identification

Environmental science

Graphene

Write a review

Note: HTML is not translated!